The evaluation of magnetic polymethacrylate-based microspheres used for solid phase DNA micro-extraction
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F15%3A00443087" target="_blank" >RIV/61389013:_____/15:00443087 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26310/15:PU113318 RIV/61989592:15110/15:33154935 RIV/00216305:26310/15:PU122750
Result on the web
<a href="http://dx.doi.org/10.3390/chromatography2020156" target="_blank" >http://dx.doi.org/10.3390/chromatography2020156</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/chromatography2020156" target="_blank" >10.3390/chromatography2020156</a>
Alternative languages
Result language
angličtina
Original language name
The evaluation of magnetic polymethacrylate-based microspheres used for solid phase DNA micro-extraction
Original language description
Using magnetic particles as a solid-phase extraction system is the most frequently used micro-technique for DNA isolation. Particles with a complete covering of magnetic cores by a polymer are hence preferred. Quantitative polymerase chain reaction (qPCR) was used for the evaluation of the polymer coating efficiency of hydrophilic magnetic poly(2-hydroxyethyl methacrylate-co-glycidyl methacrylate) (P(HEMA-co-GMA)) and poly(glycidyl methacrylate) (PGMA) microspheres with/without carboxyl groups. The inhibition effect of magnetic microspheres was identified by the shift in Cq values (ΔCq) after the addition of different amounts of microspheres to PCR mixtures. With the increase of microsphere concentrations, the shift in Cq values to higher values was usually observed. P(HEMA-co-GMA) microspheres containing carboxyl groups extinguished the fluorescence at concentrations over 2 mg mL1 in a PCR mixture without any influence on the synthesis of PCR products. No PCR products (inhibition of DNA amplification) were detected in the presence of more than 0.8 mg mL1 in the PCR mixture of PGMA microspheres. Atomic force microscopy (AFM) was used for the determination of the surface morphology of the microspheres. The microspheres were spherical, and their surface was non-porous.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
EB - Genetics and molecular biology
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Chromatography
ISSN
2227-9075
e-ISSN
—
Volume of the periodical
2
Issue of the periodical within the volume
2
Country of publishing house
CH - SWITZERLAND
Number of pages
11
Pages from-to
156-166
UT code for WoS article
—
EID of the result in the Scopus database
—