All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fast and Easy Simultaneous Determination of Riboflavin, Folic Acid, All-Trans-Retinol and α-Tocopherol in Human Serum by LC/MS/MS for Bariatric Patients

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F24%3AA2503AEG" target="_blank" >RIV/61988987:17110/24:A2503AEG - isvavai.cz</a>

  • Result on the web

    <a href="https://academic.oup.com/chromsci/article/62/8/767/7688386" target="_blank" >https://academic.oup.com/chromsci/article/62/8/767/7688386</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/chromsci/bmae035" target="_blank" >10.1093/chromsci/bmae035</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fast and Easy Simultaneous Determination of Riboflavin, Folic Acid, All-Trans-Retinol and α-Tocopherol in Human Serum by LC/MS/MS for Bariatric Patients

  • Original language description

    The aim of this study was to develop and validate methods for the determination of vitamins B2, B9, E and A in serum using liquid chromatography with mass spectrometry (MS) detection. Vitamin analysis was performed using an ultra performance liquid chromatography combined with tandem MS. The compounds were separated on a BEH C18 RP column (2.1 × 100 mm, 1.7 μm) using a gradient elution with an analysis time of 10 min. Sample preparation included protein precipitation with ethanol. The concentration range in human serum was as follows: riboflavin 5–1000 nmol/L, folic acid 2.5–250 nmol/L, α-tocopherol 0.5–100 μmol/L and all-trans-retinol 25–2500 nmol/L. Accuracy and precision were validated according to Food and Drug Administration guidelines, with coefficients of variation ranging from 3.1–11.7% and recoveries from 94.4–107.5%. Routine monitoring of the complex range of vitamins in bariatric medicine is still not common. This is despite the fact that patients are at risk for glitch deficits, especially of a neurological nature. An analytical method that allows for the complex measurement of both water-soluble and fat-soluble vitamins is important and necessary for the clinical monitoring of bariatric patients. The method we have described could benefit both clinical practice and nutritional research.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10609 - Biochemical research methods

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Chromatographic Science

  • ISSN

    0021-9665

  • e-ISSN

    1945-239X

  • Volume of the periodical

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    9

  • Pages from-to

    767-775

  • UT code for WoS article

    001240153300001

  • EID of the result in the Scopus database

    2-s2.0-85205603793