Calibration of 2D scanner with nonlinearities
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27230%2F14%3A86089845" target="_blank" >RIV/61989100:27230/14:86089845 - isvavai.cz</a>
Result on the web
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6843645" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6843645</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CarpathianCC.2014.6843645" target="_blank" >10.1109/CarpathianCC.2014.6843645</a>
Alternative languages
Result language
angličtina
Original language name
Calibration of 2D scanner with nonlinearities
Original language description
This paper deals with description of problem with nonlinearity of 2D triangulation scanners based on oscillating mirrors, used in system for measurement of diameter and ovality of the rolled tubes. It shows attempts to field software calibration of scanners, based on multiple measurements of calibration devices and comparison between measured data and required shape.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JB - Sensors, detecting elements, measurement and regulation
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the 2014 15th International Carpathian Control Conference, ICCC 2014
ISBN
978-1-4799-3528-4
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
446-449
Publisher name
IEEE Computer Society
Place of publication
Los Alamitos
Event location
Velké Karlovice
Event date
May 28, 2014
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—