Application of an intelligent fuzzy logic based sliding mode controller for frequency stability analysis in a deregulated power system using OPAL-RT platform
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F23%3A10254146" target="_blank" >RIV/61989100:27730/23:10254146 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27240/23:10254146
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S2352484723016153?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2352484723016153?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.egyr.2023.12.023" target="_blank" >10.1016/j.egyr.2023.12.023</a>
Alternative languages
Result language
angličtina
Original language name
Application of an intelligent fuzzy logic based sliding mode controller for frequency stability analysis in a deregulated power system using OPAL-RT platform
Original language description
Owing to unpredicted power demand, integration of distributed generators and parametric disparity in the system cause the power system more intricacy which in turn affects the frequency and power fluctuation criti-cally. To mitigate these phenomena, an intelligent and efficient automatic generation control (AGC) is indis-pensable. Therefore, in this paper, an intelligent and robust controller named fuzzy sliding mode controller (FSMC) has been recommended to tackle the AGC problem in a deregulated power system in the presence of distributed generators effectively. Again, to manifest its dominance over SMC, fuzzy-PID and PID controllers, dynamic response of the deregulated system under Poolco, Bilateral and Contract violation conditions has been evaluated and compared. Further, to support the FSMC controller's ability, another test model has been taken for the AGC study. The gains of these controllers have been enumerated by Gannet Optimization Algorithm (GOA) subjecting to a minimization problem. Exploration phase of GOA involves two steps, namely U-& V-shaped diving patterns of Gannets and exploitation phase again involves two steps namely sudden rotation and random walk of Gannets. These four steps ensures quick convergence of the objective function to its optimal value. Apart from transient response under different power transaction conditions, parametric uncertainties of the system, solar and wind power variation and abrupt load change have been considered to support the robustness & credibility of FSMC controller. In addition to this, the stability of the proposed model has been analyzed in the frequency domain. Finally, the MATLAB/SIMULINK based transient response has been validated by a real-time simulator using OPAL-RT-4510, Xilinx Kintex-7 FPGA software.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20200 - Electrical engineering, Electronic engineering, Information engineering
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Energy Reports
ISSN
2352-4847
e-ISSN
2352-4847
Volume of the periodical
11
Issue of the periodical within the volume
June 2024
Country of publishing house
US - UNITED STATES
Number of pages
25
Pages from-to
510-534
UT code for WoS article
001136320600001
EID of the result in the Scopus database
—