Comparison of functional fibrinogen assessment using thromboelastography with the standard von Clauss method.
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F12%3A33140097" target="_blank" >RIV/61989592:15110/12:33140097 - isvavai.cz</a>
Alternative codes found
RIV/00098892:_____/12:#0000227
Result on the web
<a href="http://dx.doi.org/10.5507/bp.2011.035" target="_blank" >http://dx.doi.org/10.5507/bp.2011.035</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2011.035" target="_blank" >10.5507/bp.2011.035</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of functional fibrinogen assessment using thromboelastography with the standard von Clauss method.
Original language description
To compare assessment of fibrinogen by thromboelastography with the standard von Clauss method. METHODS: Observational prospective study. RESULTS: Thromboelastography provides direct and complex evaluation of the entire coagulation cascade based upon changes in blood viscosity. It affects both platelets and plasma components. AIM:New application of this method measures fibrinogen contribution to coagulation as opposed to fibrinogen antigen levels measured by immunoassay. Paired samples from 117 patientsbefore cardiopulmonary bypass were compared. A moderate correlation was found between fibrinogen and functional fibrinogen with a Spearman correlation coefficient of 0.476. CONCLUSION: The functional fibrinogen test is a valid point-of-care method for fibrinogen assay with a moderate correlation to the standard method.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/NS9614" target="_blank" >NS9614: Influence of biocompatible coated heart lung machine tubing set on fibrinogen function, assessed by the TEG Functional Fibrinogen</a><br>
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomedical Papers-Olomouc
ISSN
1213-8118
e-ISSN
—
Volume of the periodical
156
Issue of the periodical within the volume
3
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
2
Pages from-to
260-261
UT code for WoS article
—
EID of the result in the Scopus database
—