Transcranial sonography and (123)I-FP-CIT single photon emission computed tomography in movement disorders
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F14%3A33150662" target="_blank" >RIV/61989592:15110/14:33150662 - isvavai.cz</a>
Alternative codes found
RIV/00843989:_____/14:E0104146
Result on the web
<a href="http://dx.doi.org/10.1016/j.ultrasmedbio.2014.05.014" target="_blank" >http://dx.doi.org/10.1016/j.ultrasmedbio.2014.05.014</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ultrasmedbio.2014.05.014" target="_blank" >10.1016/j.ultrasmedbio.2014.05.014</a>
Alternative languages
Result language
angličtina
Original language name
Transcranial sonography and (123)I-FP-CIT single photon emission computed tomography in movement disorders
Original language description
Diagnosis of Parkinson's disease (PD) can be difficult in the early stages of the disease. The aim of the study described here was to assess the correlation between transcranial sonography (TCS) and (123)I-FP-CIT ([(123)I]ioflupane, N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-[(123)I]iodophenyl)nortropane) SPECT (single photon emission computed tomography) findings and the diagnosis of PD. A total of 49 patients were enrolled in the study: 29 patients with PD, 7 patients with other parkinsonian syndromes, 11 patients with essential tremor and 2 with psychogenic movement disorder. Substantia nigra echogenicity was measured using TCS. SPECT was performed using DaTSCAN ([(123)I]ioflupane). TCS and SPECT findings were correlated in 84% of patients, with kappa = 0.62 (95% confidence interval: 0.38-0.86). TCS-measured substantia nigra echogenicity and SPECT-measured striatal binding ratio were negatively correlated (r = -0.326, p = 0.003). TCS/SPECT sensitivity, specificity and positive
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FH - Neurology, neuro-surgery, nuero-sciences
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Ultrasound in Medicine and Biology
ISSN
0301-5629
e-ISSN
—
Volume of the periodical
40
Issue of the periodical within the volume
10
Country of publishing house
US - UNITED STATES
Number of pages
7
Pages from-to
2365-2371
UT code for WoS article
000343144400006
EID of the result in the Scopus database
—