All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

MEKC Determination of Nilutamide in Human Serum Using Sweeping in High Salt Sample Matrix

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F11%3A33116273" target="_blank" >RIV/61989592:15310/11:33116273 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/s10337-011-2019-1" target="_blank" >http://dx.doi.org/10.1007/s10337-011-2019-1</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s10337-011-2019-1" target="_blank" >10.1007/s10337-011-2019-1</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    MEKC Determination of Nilutamide in Human Serum Using Sweeping in High Salt Sample Matrix

  • Original language description

    The determination of the antiandrogen drug nilutamide in human serum by MEKC using flutamide as an internal standard is described. Several parameters influencing the separation, such as the running electrolyte composition concerning the micelle concentration and pH, are discussed. MEKC separation was achieved within 7 min using 50 mM sodium borate pH 9.0 with the addition of 50 mM sodium dodecylsulfate at +20 kV. The proposed method was applied to determination of nilutamide in spiked human serum samples after protein precipitation with acetonitrile. The increasing of sensitivity for determination of nilutamide in serum was done by sweeping in a high salt concentration sample matrix when the injection of a larger volume of sample diluted in 150 mM NaClwas applied. The limit of detection after the preconcentration step for nilutamide was 26 mu g L(-1).

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED2.1.00%2F03.0058" target="_blank" >ED2.1.00/03.0058: Regional Centre of Advanced Technologies and Materials</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Chromatographia

  • ISSN

    0009-5893

  • e-ISSN

  • Volume of the periodical

    74

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    5

  • Pages from-to

    151-155

  • UT code for WoS article

    000291745400019

  • EID of the result in the Scopus database