Chiral supercritical fluid chromatography of monoacylglycerol and diacylglycerol enantiomers in biological samples: Adjusting selectivity via column coupling
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62690094%3A18470%2F25%3A50022121" target="_blank" >RIV/62690094:18470/25:50022121 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11160/25:10515324
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0021967324009634" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0021967324009634</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2024.465591" target="_blank" >10.1016/j.chroma.2024.465591</a>
Alternative languages
Result language
angličtina
Original language name
Chiral supercritical fluid chromatography of monoacylglycerol and diacylglycerol enantiomers in biological samples: Adjusting selectivity via column coupling
Original language description
The distinction of lipid isomers is gaining more attention in lipidomics due to their different biochemical properties in the organism. Herein, we aimed to develop a method for the analysis of monoacylglycerol (MG) and diacylglycerol (DG) enantiomers in biological samples using chiral supercritical fluid chromatography and mass spectrometry (SFC-MS). Amylose-based chiral columns showed a certain degree of separation of MG and DG isomers, but low selectivity for the acylglycerol classes in total lipid extracts, which could not be improved by modifier composition or other chromatographic conditions. The coelution of MG and DG enantiomers with highly concentrated triacylglycerols (TGs) negatively affected their MS determination based on the peak area ratio, therefore the interclass selectivity of chiral SFC was adjusted by coupling with an achiral column. The connection of the amylose tris-(3,5-dimethylphenylcarbamate) chiral column with octadecyl achiral column using a methanol as a modifier provided an excellent interclass separation of acylglycerols with the resolution of 5.53 and 15.17 for oleic acid-based MG/DG and DG/TG classes, respectively. The developed method enabled the determination of MG and DG enantiomers in complex total lipid extracts of biological samples in a 15 min gradient without time-consuming sample prefractionation. Chiral SFC-MS analysis of egg yolk, human plasma, and porcine brain samples showed different ratios of enantiomers, suggesting their unique roles within each sample type.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/GA24-12234S" target="_blank" >GA24-12234S: Evaluation of chiral SFC-MS for the analysis of positional isomers and enantiomers of biologically significant lipids</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
1873-3778
Volume of the periodical
1740
Issue of the periodical within the volume
January
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
"Article Number: 465591"
UT code for WoS article
001386574500001
EID of the result in the Scopus database
2-s2.0-85211638747