Percutaneous Endoluminal Radiofrequency Ablation of Occluded Biliary Metal Stent in Malignancy Using Monopolar Technique: A Feasibility Study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F22%3A00076097" target="_blank" >RIV/65269705:_____/22:00076097 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/22:00125706
Result on the web
<a href="https://link.springer.com/10.1007/s00270-022-03097-z" target="_blank" >https://link.springer.com/10.1007/s00270-022-03097-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00270-022-03097-z" target="_blank" >10.1007/s00270-022-03097-z</a>
Alternative languages
Result language
angličtina
Original language name
Percutaneous Endoluminal Radiofrequency Ablation of Occluded Biliary Metal Stent in Malignancy Using Monopolar Technique: A Feasibility Study
Original language description
Purpose To prove feasibility and safety of percutaneous endoluminal radiofrequency ablation (eRFA) using a monopolar approach in treatment of occluded biliary stent in malignancy. Materials and Methods The study included 11 patients with occluded biliary metal stent that had been implanted due to malignant biliary obstruction. All underwent metal stent recanalization by percutaneous eRFA in monopolar setting. Sixteen eRFA procedures were performed under fluoroscopic guidance with an EndoHPB 8F radiofrequency ablation catheter. The effect of stent recanalization was assessed based upon change from pre- to post-procedural diameter of the patent lumen of the metal stent (Wilcoxon test), primary and secondary stent patency (compared by log-rank test), catheter-free period, and overall survival. Adverse events were evaluated according to Common Terminology Criteria for Adverse Events (CTCEA) 4.0. Results Recanalization of the metal stent by monopolar radiofrequency ablation was successful in all 11 patients. Diameter of the patent lumen of the stent significantly widened after the eRFA inside the stent (median 2 vs. 7 mm, p = 0.003). Grade 1 complications were observed in one-third of procedures. Median stent patency after recanalization by eRFA was non-inferior to primary metal stent patency (154 vs. 161 days, p = 0.27). Median catheter-free survival and overall survival after stent recanalization were 149 and 210 days, respectively. Conclusion Endoluminal radiofrequency ablation in monopolar setting was shown to be a feasible and safe method for recanalization of occluded biliary metal stents.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
<a href="/en/project/NU21-08-00561" target="_blank" >NU21-08-00561: The use of irreversible electroporation and high frequency irreversible electroporation for treatment of metal stent occlusion</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Cardiovascular and Interventional Radiology
ISSN
0174-1551
e-ISSN
1432-086X
Volume of the periodical
45
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
873-878
UT code for WoS article
000761841200001
EID of the result in the Scopus database
2-s2.0-85125243659