Hygrothermal Performance of Interior Thermal Insulation Systems
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F02%3A01078762" target="_blank" >RIV/68407700:21110/02:01078762 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Hygrothermal Performance of Interior Thermal Insulation Systems
Original language description
Hygrothermal performance of a three layer interior thermal insulation system consisting of water vapor retarder, capillary active thermal insulation material on the mineral wool basis and internal light plaster is tested by computational analysis using DELPHIN 4.1 As the capillary active thermal insulation, the dual density material DU developed by Rockwool, SA is used. Temperature, relative humidity and overhygroscopic moisture fields are calculated for the time period of several years and the hygrothermal performance of the system is assessed. Computational results show a very good hygrothermal performance of the chosen interior thermal insulation system for a brick wall, no overhygroscopic moisture appears in the structure during the period of fiveconsecutive years
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JM - Structural engineering
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2002
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
4th Ph.D. Symposium in Civil Engineering
ISBN
3-935065-09-4
ISSN
—
e-ISSN
—
Number of pages
6
Pages from-to
8-13
Publisher name
Springer VDI Verlag
Place of publication
Düsseldorf
Event location
Mnichov
Event date
Sep 19, 2002
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—