A Method for Evaluation of Non-Uniform Radiant-Convective Load on Human Body during Mental Work
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00317239" target="_blank" >RIV/68407700:21110/17:00317239 - isvavai.cz</a>
Result on the web
<a href="https://ojs.cvut.cz/ojs/index.php/ap/article/view/4173" target="_blank" >https://ojs.cvut.cz/ojs/index.php/ap/article/view/4173</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/AP.2017.57.0340" target="_blank" >10.14311/AP.2017.57.0340</a>
Alternative languages
Result language
angličtina
Original language name
A Method for Evaluation of Non-Uniform Radiant-Convective Load on Human Body during Mental Work
Original language description
The objective of this study was to develop a documentation for the amendment of the microclimatic part of the Czech Government Regulation, particularly in a non-uniform radiant-convective load evaluation. Changes in regulation were made based on experimental data obtained on a group of experimental individuals in a climatic chamber. One of the objectives of the climatic chamber experiments was to evaluate whether there was a possibility to use an alternative method, which utilizes a new value – stereotemperature, for the assessment. A group of 24 women was exposed to a non-uniform radiant-convective load in a climatic chamber for 1 hour during their computer work. Measurements were divided according to the globe temperature into 3 stages. The physical parameters of air were continuously measured: the air temperature, globe temperature, air velocity, radiant temperature, relative humidity, stereotemperature and physiological parameters. Thermal sensations of experimental subjects were expressed in the seven-point scale according to EN ISO 7730. The thermal sensation correlated very well with the difference of stereotemperature and the globe temperature. The stereotemperature correlated very well with the radiant temperature. In this work, the composed equations were used to develop the limit values for the thermal stress evaluation in the uniform and non-uniform thermal environment at workplaces. It is possible to determine how the body of an exposed person perceives the non-uniform climatic conditions in the indoor environment, by adding the stereotemperature to government regulations.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20101 - Civil engineering
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta Polytechnica
ISSN
1210-2709
e-ISSN
—
Volume of the periodical
57
Issue of the periodical within the volume
5
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
8
Pages from-to
340-347
UT code for WoS article
000418522700005
EID of the result in the Scopus database
2-s2.0-85033395936