All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Ultimate-frequency Based Three-pole Dominant Placement in Delayed PID Control Loop

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F12%3A00197873" target="_blank" >RIV/68407700:21220/12:00197873 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.3182/20120622-3-US-4021.00002" target="_blank" >http://dx.doi.org/10.3182/20120622-3-US-4021.00002</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3182/20120622-3-US-4021.00002" target="_blank" >10.3182/20120622-3-US-4021.00002</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Ultimate-frequency Based Three-pole Dominant Placement in Delayed PID Control Loop

  • Original language description

    Besides its original use in the state space based design the pole assignment is also applied in tuning the PID controllers where only an approximate model is considered. However, the common assumption of time delay in this model imposes the limitation that only such pole prescription which results in the dominant pole assignment can be effective in tuning the control loop with time delay. The three parameter PID controller is capable to assign just three poles and a dominance guarantee of their prescription is crucial in the pole placement. A novel method of selecting a trio of numbers p1,2,3 to make them the dominant poles of the control loop is dealt with in the paper with an additional minimizing the absolute error integral. The dominance of each of the placement trials is checked by an argument increment criterion and an optimum of relative damping of the response is assessed to minimize the control error integral. The disturbance rejection response as the critical point of view in time delay process control is taken as criterion in the controller design.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    BC - Theory and management systems

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 10th IFAC Workshop on Time Delay Systems

  • ISBN

    978-3-902823-04-5

  • ISSN

    1474-6670

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    150-155

  • Publisher name

    IFAC

  • Place of publication

    New York

  • Event location

    Boston, MA

  • Event date

    Jun 22, 2012

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article