All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F16%3A00303102" target="_blank" >RIV/68407700:21230/16:00303102 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.5370/JEET.2016.11.6.1744" target="_blank" >http://dx.doi.org/10.5370/JEET.2016.11.6.1744</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.5370/JEET.2016.11.6.1744" target="_blank" >10.5370/JEET.2016.11.6.1744</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Waveguide Applicator System for Head and Neck Hyperthermia Treatment

  • Original language description

    The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the treatment planning based on the optimization process made through the SEMCAD X software is added to show the steering possibilities of SAR and thereby temperature distribution. Using treatment planning software, we proved that the SAR and temperature distribution can be effectively controlled (by amplitude and phase changing) improving the SAR and temperature target coverage approximately by 20 %. For the proposed applicator system analysis and quantitative evaluation of two parameters 25 % iso-SAR and 41°C iso-temperature contours in the treatment area with the respect to sensitive structures in treatment area were defined. To verify our simulation results, the real measurement of reflectivity coefficient as well as the temperature distribution in a homogenous phantom were performed.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Electrical Engineering & Technology

  • ISSN

    1975-0102

  • e-ISSN

  • Volume of the periodical

    11

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    KR - KOREA, REPUBLIC OF

  • Number of pages

    10

  • Pages from-to

    1744-1753

  • UT code for WoS article

    000387097700024

  • EID of the result in the Scopus database

    2-s2.0-84991246375