Organ and effective doses from verification techniques in Image-Guided Radiotherapy

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F11%3A00191466" target="_blank" >RIV/68407700:21340/11:00191466 - isvavai.cz</a>

  • Alternative codes found

    RIV/86652052:_____/11:#0000032

  • Result on the web

    <a href="http://rpd.oxfordjournals.org/cgi/reprint/ncr335?ijkey=ZCWsw7OMD7Z5ruS&keytype=ref" target="_blank" >http://rpd.oxfordjournals.org/cgi/reprint/ncr335?ijkey=ZCWsw7OMD7Z5ruS&keytype=ref</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncr335" target="_blank" >10.1093/rpd/ncr335</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Organ and effective doses from verification techniques in Image-Guided Radiotherapy

  • Original language description

    The purpose of this work was to evaluate organ doses and effective doses from three verification techniques in Image-Guided Radiotherapy: from kilovoltage (kV) cone beam CT (CBCT) scans, from two orthogonal kV images, and from two orthogonal megavoltage(MV) images for two different treatment sites: pelvis and head and neck (H&N). For comparison reasons, organ doses and effective doses from prostate and H&N radiotherapy were also evaluated. Measurements of organ doses were performed in a male anthropomorphic Rando phantom by means of thermoluminescent dosemeters (TLDs) MCP-N. In our investigation, measured organ doses from one CBCT scan, from two MV images, and from two kV images of pelvis represent typically 1 to 6 %, 1 to 10 %, and 0.05 to 1 %, respectively, of organ doses resulting from one fraction of prostate radiotherapy. The maximum effective doses from one CBCT scan, two kV images and two MV images of pelvis are 5.6 mSv, 0.8 mSv and 11.9 mSv, respectively.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/JC_4%2F2009" target="_blank" >JC_4/2009: Evaluation and verification of patient doses during advanced radiation therapy techniques (IMRT, IGRT).</a><br>

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

  • Volume of the periodical

    147

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    4

  • Pages from-to

    277-280

  • UT code for WoS article

    000296355500065