Characterization of the bias between oxygen saturation measured by pulse oximetry and calculated by an arterial blood gas analyzer in critcally ill neonates

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F17%3A00324261" target="_blank" >RIV/68407700:21460/17:00324261 - isvavai.cz</a>

  • Result on the web

    <a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/4661" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/4661</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Characterization of the bias between oxygen saturation measured by pulse oximetry and calculated by an arterial blood gas analyzer in critcally ill neonates

  • Original language description

    Continuous monitoring of oxygenation with pulse oximetry is the standard of care for critically ill neonates. A better understanding of its measurement bias compared to arterial oxygen saturation could be helpful both for the clinician and researcher. Towards that end, we examined the electronic database from a large neonatal ICU. From a 24-month period we identified 25,032 paired SpO2-SaO2 measurements from 1,007 infants who were receiving supplemental oxygen during mechanical ventilation. We found that SpO2 was consistently higher than SaO2. The size of the bias was fairly constant when SpO2 was between 75-93%, above which it dropped steadily. The median size of this bias was 1% SpO2 during hyperoxemia (SpO2 97-100%) with a median variation of 1.3% above and below. During periods of hypoxemia (SpO2 75-85%) and normoxemia (SpO2 89-93%) the bias was approximately 5% SpO2, with a median variation of 5% above and below. 2017, Czech Medical Association J.E. Purkyne. All rights reserved.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    20601 - Medical engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Lékař a technika – Clinician and Technology

  • ISSN

    0301-5491

  • e-ISSN

    2336-5552

  • Volume of the periodical

    47

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    5

  • Pages from-to

    130-134

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85044406174