Inter-Finger Variability of SpO2 During Hypoxemia and Step Resaturation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21460%2F25%3A00386004" target="_blank" >RIV/68407700:21460/25:00386004 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/healthcare13202648" target="_blank" >https://doi.org/10.3390/healthcare13202648</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/healthcare13202648" target="_blank" >10.3390/healthcare13202648</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Inter-Finger Variability of SpO2 During Hypoxemia and Step Resaturation

  • Original language description

    Background: Pulse oximetry is a non-invasive method for continuous monitoring of peripheral blood oxygen saturation (SpO2) to estimate arterial oxygen saturation. Previous studies suggested that SpO2 measurements show variability depending on the particular finger that is used for measurement. To date, no study has compared all fingers for SpO2 under hypoxemia and during continuous simultaneous monitoring with randomization of finger sensor placement. Objectives: The aim of this study was to assess the inter-finger variability of SpO2 values during sequential desaturation and step resaturation. Methods: Forty-three out of forty-five healthy participants (age 23.0 ± 1.8 years, BMI 24.0 ± 4.4 kg.m-2) completed the experimental assessment with short-term induced hypoxemia by consecutive inhalation of three prepared gas mixtures with reduced oxygen concentrations (14%, 12%, and 10%). SpO2 was measured continuously with the Masimo Radical-97 (Masimo Corp., Irvine, CA, USA) pulse oximeters. Results: The SpO2 measured on the thumb was lower than all other fingers by 0.6% to 0.7% SpO2, a systematic difference that is less than the clinically accepted accuracy of oximeters. No difference in SpO2 dynamics was found between any of the fingers during step resaturation. Conclusions: A systematic difference in measured SpO2 exists between the thumb and the other fingers during desaturation, which should be considered at least as well as the impact of the performance of a particular oximeter, sensor placement or anatomical variability.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20601 - Medical engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Healthcare

  • ISSN

    2227-9032

  • e-ISSN

    2227-9032

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    20

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    11

  • Pages from-to

    1-11

  • UT code for WoS article

    001601610700001

  • EID of the result in the Scopus database

    2-s2.0-105020078493