Multiple Laser Spot Tracking with Position Sensitive Detectors
The paper deals with an application of Position Sensitive Detectors (PSD) to a system for tracking of multiple laser spots on a screen. In contrast to classical multi-element CCD devices PSDs are comprised of a monolithic <...
JA - Elektronika a optoelektronika, elektrotechnika
- 2004 •
- D
Rok uplatnění
D - Stať ve sborníku
Application of Possitional Sensitive Detectors.
The paper deals with an application of Position Sensitive Detectors (PSD) to a system for tracking of laser spots on a screen. In contrast to classical multi-element CCD devices PSDs are comprised of a monolithic detect...
JA - Elektronika a optoelektronika, elektrotechnika
- 2004 •
- D
Rok uplatnění
D - Stať ve sborníku
Enhancement of X-Ray Diffraction Measurement of Residual Stresses by Using of Area Position Sensitive Detector
The aim of the contribution is to present the enhanced arrangement of X-ray diffraction technique equipped with an area sensitive position detector and to illustrate its capabilities when applied in aircraft industry....
JG - Hutnictví, kovové materiály
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
New Data Collection Subsystem for Powder Neutron Diffractometer with Position Sensitive Detectors.
Project INDECS (Integrated Diffraction Experiment Control System) is a newly developed system created for the purpose of data aquisition from, and controlling of the upgraded version of the KSN-2 powder neutron diffractometer equipped with Positi...
BM - Fyzika pevných látek a magnetismus
- 2012 •
- Jx •
- Link
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Výsledek na webu
New Data Collection Subsystem for Powder Neutron Diffractometer with Position Sensitive Detectors
Project INDECS (Integrated Neutron Diffraction Experiment Control System) is a newly developed software system created for the purpose of data acquisition from, and controlling of the upgraded version of the KSN-2 powder neutron diffractometer equipp...
BM - Fyzika pevných látek a magnetismus
- 2011 •
- O
Rok uplatnění
O - Ostatní výsledky
Position sensitive neutron detector with VATA GP8
Position sensitive detector of thermal neutrons consists of 4 chips VATA GP8 and two strip sensors. The direction of strips is perpendicular providing two-dimensional coordinate. Convertor material with 6Li is placed betwee...
Nuclear physics
- 2017 •
- Gfunk
Rok uplatnění
Gfunk - Funkční vzorek
Enhancement of X-Ray Diffraction Measurement of Residual Stresses by Using of Area Position Sensitive Detector
The aim of this contribution is to present the enhanced arrangement of X-ray diffraction technique equipped with an area sensitive position detector and to illustrate its capabilities when applied in aircraft industry....
JG - Hutnictví, kovové materiály
- 2008 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Single channel analyzer
Single channel analyzer for position sensitive activation analysis makes possible coincidence measuring with high sensitive germanium detector and position sensitive Timepix detector. Ana...
JC - Počítačový hardware a software
- 2008 •
- Gfunk
Rok uplatnění
Gfunk - Funkční vzorek
Texture Investigation with Position Sensitive Detectors on the KSN-2 Powder Neutron Diffractometer
The research activities of the Laboratory of Neutron Diffraction (Faculty of Nuclear Sciences and Physical Engineering CTU Prague)are focused on neutron scattering investigations in solid state physics and science....
BM - Fyzika pevných látek a magnetismus
- 2002 •
- D
Rok uplatnění
D - Stať ve sborníku
Position Sensitive Nuclear Spectroscopy with Pixel Detectors
State-of-the-art hybrid semiconductor pixel detectors such as Medipix2 are suitable for energy- and position-sensitive nuclear spectroscopy. In addition to excellent energy- and spatial-resolution, these devices can operate...
BG - Jaderná, atomová a molekulová fyzika, urychlovače
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku