Filtry
The importance of measuring ventilation air in homes and buildings for the determination averted doses from inhalation of buildings from contaminated outdoor air by radioactive substances
for the transfer of contaminated air into dwellings and buildings is exchange rate between the significance of air exchange rate by theoretical courses in time of indoor concentrations screening ...
DL - Jaderné odpady, radioaktivní znečištění a kontrola
- 2015 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Windows from air infilration point of view
The paper deals with problems of window air infiltration, reduction of heat losses by ventilation and requirements for hygienic limits of air exchange rate in rooms....
JN - Stavebnictví
- 2006 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Analysis of leakage influence within capillary heat pipe recuperative heat exchanger
The paper analyses the leakage of air-to-air recovery heat exchanger consisting of the recovery exchanger prototype was tested in a pigsty. The analysis focuses on how the exchanger leakage affects the hea...
JN - Stavebnictví
- 2007 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
STABILISATION OF THE VENTILATION AIR TEMPERATURE WITH THE AIR-PCM HEAT EXCHANGER
The possibility of using an air-PCM heat exchanger for stabilization. The air-PCM heat exchanger was assumed to contain 100 CSM panels filled with PCM rates of ventilation air were explored in the...
JN - Stavebnictví
- 2016 •
- D
Rok uplatnění
D - Stať ve sborníku
Relevance of ventilation for determination of an averted dose from inhalation of outdoor air contaminated with radioactive substances in dwellings and buildings
Indoor air exchange rate is the crucial factor affecting also the averted dose indoor air exchange rate and the averted dose the results of an average air exchange observed indoo...
Environmental sciences (social aspects to be 5.7)
- 2017 •
- JSC
Rok uplatnění
JSC - Článek v periodiku v databázi SCOPUS
Air flow and air exchange rate in collector Rudolfinum
The result is information about the function of HVAC systems providing ventilation collector "RUDOLFINUM". The balance of air exchange in the collector....
JE - Nejaderná energetika, spotřeba a užití energie
- 2015 •
- Vsouhrn
Rok uplatnění
Vsouhrn - Souhrnná výzkumná zpráva
Verification of the Method of Deposition Rate Determination in an Experimental Chambre
concentration time decay is influenced not only by the particle deposition rate, but the forced air exchange rate by the aerosol sampling, too. The method is based calculation, where the forced air ex...
JE - Nejaderná energetika, spotřeba a užití energie
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Radon entry rate analyses using in-situ tracer gas method aplication
entry rate and air exchange rate alteration. For the purpose of detailed analysis exchange rate reduction as a result of home energy retrofits. In case of refurbishment andair-exchange <...
DN - Vliv životního prostředí na zdraví
- 2013 •
- O
Rok uplatnění
O - Ostatní výsledky
State-space model for multi-comparamental indoor radon concentration monitoring
An application of the statistical State space approach for estimation interzonal air exchange rate during multizonal radon measurements is outlined....
DL - Jaderné odpady, radioaktivní znečištění a kontrola
- 2007 •
- D
Rok uplatnění
D - Stať ve sborníku
Peak-shaving of ventilation air temperature with an air-PCM heat exchanger – a simulation study
The possibility of using an air-PCM heat exchanger for peak-shaving The air-PCM heat exchanger was assumed to contain 100 CSM panels with PCM rates of ventilation air were explored in the study. T...
JN - Stavebnictví
- 2016 •
- D
Rok uplatnění
D - Stať ve sborníku
- 1 - 10 z 92 941