Analysis of Nonstandard and Home-Made Explosives and Post-Blast Residues in Forensic Practice
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00007064%3AK01__%2F14%3A%230000081" target="_blank" >RIV/00007064:K01__/14:#0000081 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1117/12.2050121" target="_blank" >http://dx.doi.org/10.1117/12.2050121</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2050121" target="_blank" >10.1117/12.2050121</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of Nonstandard and Home-Made Explosives and Post-Blast Residues in Forensic Practice
Popis výsledku v původním jazyce
Nonstandard and home-made explosives may constitute a considerable threat and as well as a potential material for terrorist activities. Mobile analytical devices, particularly Raman, or also FTIR spectrometers are used for the initial detection. Varioussorts of phlegmatizers (moderants) to decrease sensitivity of explosives were tested, some kinds of low viscosity lubricants yielded very good results. If the character of the substance allows it, phlegmatized samples are taken in the amount of approx. 0.3g for a laboratory analysis. Various separation methods and methods of concentrations of samples from post-blast scenes were tested. A wide range of methods is used for the laboratory analysis. XRD techniques capable of a direct phase identification ofthe crystalline substance, namely in mixtures, have highly proved themselves in practice for inorganic and organic phases. SEM-EDS/WDS methods are standardly employed for the inorganic phase. In analysing post-blast residues, there are v
Název v anglickém jazyce
Analysis of Nonstandard and Home-Made Explosives and Post-Blast Residues in Forensic Practice
Popis výsledku anglicky
Nonstandard and home-made explosives may constitute a considerable threat and as well as a potential material for terrorist activities. Mobile analytical devices, particularly Raman, or also FTIR spectrometers are used for the initial detection. Varioussorts of phlegmatizers (moderants) to decrease sensitivity of explosives were tested, some kinds of low viscosity lubricants yielded very good results. If the character of the substance allows it, phlegmatized samples are taken in the amount of approx. 0.3g for a laboratory analysis. Various separation methods and methods of concentrations of samples from post-blast scenes were tested. A wide range of methods is used for the laboratory analysis. XRD techniques capable of a direct phase identification ofthe crystalline substance, namely in mixtures, have highly proved themselves in practice for inorganic and organic phases. SEM-EDS/WDS methods are standardly employed for the inorganic phase. In analysing post-blast residues, there are v
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CA - Anorganická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Proceedings of the SPIE
ISSN
0277-786X
e-ISSN
—
Svazek periodika
9073
Číslo periodika v rámci svazku
5/2014
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000342428900024
EID výsledku v databázi Scopus
—