3D Multislice and Cone-beam Computed Tomography Systems for Dental Identification.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00007064%3AK01__%2F17%3AN0000029" target="_blank" >RIV/00007064:K01__/17:N0000029 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/17:10374061 RIV/00064203:_____/17:10374061
Výsledek na webu
<a href="https://www.ncbi.nlm.nih.gov/pubmed/28364571" target="_blank" >https://www.ncbi.nlm.nih.gov/pubmed/28364571</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14712/23362936.2017.2" target="_blank" >10.14712/23362936.2017.2</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
3D Multislice and Cone-beam Computed Tomography Systems for Dental Identification.
Popis výsledku v původním jazyce
3D Multislice and Cone-beam computed tomography (CBCT) in forensic odontology has been shown to be useful not only in terms of one or a few of dead bodies but also in multiple fatality incidents. 3D Multislice and Cone-beam computed tomography and digital radiography were demonstrated in a forensic examination form. 3D images of the skull and teeth were analysed and validated. The image acquisition was instantaneous; the images were able to be optically enlarged, measured, superimposed and compared prima vista or using special software and exported as a file. Our study demonstrated that CBCT imaging offers less image artifacts, low image reconstruction times, mobility of the unit and considerably lower equipment cost.
Název v anglickém jazyce
3D Multislice and Cone-beam Computed Tomography Systems for Dental Identification.
Popis výsledku anglicky
3D Multislice and Cone-beam computed tomography (CBCT) in forensic odontology has been shown to be useful not only in terms of one or a few of dead bodies but also in multiple fatality incidents. 3D Multislice and Cone-beam computed tomography and digital radiography were demonstrated in a forensic examination form. 3D images of the skull and teeth were analysed and validated. The image acquisition was instantaneous; the images were able to be optically enlarged, measured, superimposed and compared prima vista or using special software and exported as a file. Our study demonstrated that CBCT imaging offers less image artifacts, low image reconstruction times, mobility of the unit and considerably lower equipment cost.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AC - Archeologie, antropologie, etnologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VF20152015041" target="_blank" >VF20152015041: Rozvoj vybraných metod pro kriminalistickou identifikaci osob a věcí - 2. etatpa</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Prague Medical Report
ISSN
1214-6994
e-ISSN
—
Svazek periodika
118
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
14-25
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—