Surface Morphology of Three-Dimensionally Printed Replicas of Upper Dental Arches.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00007064%3AK01__%2F20%3AN0000048" target="_blank" >RIV/00007064:K01__/20:N0000048 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21730/20:00347476 RIV/00216208:11130/20:10413976 RIV/60461373:22340/20:43920989 RIV/00064203:_____/20:10413976 RIV/68378271:_____/20:00552105
Výsledek na webu
<a href="https://doi.org/10.3390/app10165708" target="_blank" >https://doi.org/10.3390/app10165708</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/app10165708" target="_blank" >10.3390/app10165708</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Surface Morphology of Three-Dimensionally Printed Replicas of Upper Dental Arches.
Popis výsledku v původním jazyce
The aim of our study was to analyze the precision of fused-deposition modeling (FDM), polyjet technology (PJ), stereolithography (SLA) and selective laser sintering (SLS) and to evaluate some interesting indications of these methods in clinical practice. Forty upper dental arches were scanned using a 3Shape Trios 3R optical scanner system and 3D models were made. An Atos II 400 optical 3D scanner was used for calculating the coordinates of points by optical triangulation, photogrammetry and fringe projection. Each model was scanned from a minimum of 56 positions to evaluate global coordinates. Surface morphology was evaluated with an Alpha Step IQ profilometer and a JSM 5510 LV scanning electron microscope. From the measurements in cross-sections it was evident that the deviation shifted by approximately 0.1 mm. The smoothest and most homogeneous sample was SLA. SLS and SLA samples showed the most similar results in comparison of perpendicular directions (homogeneity). FDM and PJ materials exhibited significantly greater roughness in the printing direction than in the perpendicular one, which is most likely caused by the technology selected and/or print parameters. Clinical applications have demonstrated unusual treatment options for patients with rare diseases.
Název v anglickém jazyce
Surface Morphology of Three-Dimensionally Printed Replicas of Upper Dental Arches.
Popis výsledku anglicky
The aim of our study was to analyze the precision of fused-deposition modeling (FDM), polyjet technology (PJ), stereolithography (SLA) and selective laser sintering (SLS) and to evaluate some interesting indications of these methods in clinical practice. Forty upper dental arches were scanned using a 3Shape Trios 3R optical scanner system and 3D models were made. An Atos II 400 optical 3D scanner was used for calculating the coordinates of points by optical triangulation, photogrammetry and fringe projection. Each model was scanned from a minimum of 56 positions to evaluate global coordinates. Surface morphology was evaluated with an Alpha Step IQ profilometer and a JSM 5510 LV scanning electron microscope. From the measurements in cross-sections it was evident that the deviation shifted by approximately 0.1 mm. The smoothest and most homogeneous sample was SLA. SLS and SLA samples showed the most similar results in comparison of perpendicular directions (homogeneity). FDM and PJ materials exhibited significantly greater roughness in the printing direction than in the perpendicular one, which is most likely caused by the technology selected and/or print parameters. Clinical applications have demonstrated unusual treatment options for patients with rare diseases.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20505 - Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics; filled composites)
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20152020040" target="_blank" >VI20152020040: Plastická a maxilofaciální chirurgie v kontextu forenzní portrétní identifikace osob</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Sciences
ISSN
2076-3417
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
16
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000565616700001
EID výsledku v databázi Scopus
—