USE OF MOBILE FANS TO ENSURE THE SAFETY OF ROAD TUNNELS DURING FIRE

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00007064%3AK13__%2F19%3AN0000052" target="_blank" >RIV/00007064:K13__/19:N0000052 - isvavai.cz</a>

  • Nalezeny alternativní kódy

    RIV/00007064:K13__/19:N0000022 RIV/61989100:27200/19:10243231 RIV/61989100:27230/19:10243231

  • Výsledek na webu

    <a href="https://transportmeans.ktu.edu/wp-content/uploads/sites/307/2018/02/Transport-means-2019-Part-1.pdf" target="_blank" >https://transportmeans.ktu.edu/wp-content/uploads/sites/307/2018/02/Transport-means-2019-Part-1.pdf</a>

  • DOI - Digital Object Identifier

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    USE OF MOBILE FANS TO ENSURE THE SAFETY OF ROAD TUNNELS DURING FIRE

  • Popis výsledku v původním jazyce

    Tunnel structures are usually underground structures forming the infrastructure of a territory that has several specifics. Special requirements are also related to ensuring the safety of tunnels. One of the most important devices involved in ensuring safety is ventilation that is designed in many variants. Ventilation is a technical device where the possibility of defect or failure cannot be completely excluded. An alternative solution to ensure fire ventilation for tunnels can be the mobile fans of rescue units. The resulting effect achieved by mobile fans, especially the air flow velocity in the tunnel, is influenced by many aspects, including the length of the tunnel, the tunnel cross-section, the influence of external conditions, etc. The possibility of using mobile fans will be described in a case study based on a real experiment. Results of the case study show that in some cases mobile fans can be a suitable solution for directing the movement of smoke resulting from fires in a road tunnel. They can provide good conditions for firefighting. However, this is an extraordinary solution that can only complement the design solution for emergency incidents in a road tunnel. Standard tunnel safety systems, including ventilation, cannot be replaced by mobile fans.

  • Název v anglickém jazyce

    USE OF MOBILE FANS TO ENSURE THE SAFETY OF ROAD TUNNELS DURING FIRE

  • Popis výsledku anglicky

    Tunnel structures are usually underground structures forming the infrastructure of a territory that has several specifics. Special requirements are also related to ensuring the safety of tunnels. One of the most important devices involved in ensuring safety is ventilation that is designed in many variants. Ventilation is a technical device where the possibility of defect or failure cannot be completely excluded. An alternative solution to ensure fire ventilation for tunnels can be the mobile fans of rescue units. The resulting effect achieved by mobile fans, especially the air flow velocity in the tunnel, is influenced by many aspects, including the length of the tunnel, the tunnel cross-section, the influence of external conditions, etc. The possibility of using mobile fans will be described in a case study based on a real experiment. Results of the case study show that in some cases mobile fans can be a suitable solution for directing the movement of smoke resulting from fires in a road tunnel. They can provide good conditions for firefighting. However, this is an extraordinary solution that can only complement the design solution for emergency incidents in a road tunnel. Standard tunnel safety systems, including ventilation, cannot be replaced by mobile fans.

Klasifikace

  • Druh

    D - Stať ve sborníku

  • CEP obor

  • OECD FORD obor

    50703 - Transport planning and social aspects of transport (transport engineering to be 2.1)

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/VI20152020009" target="_blank" >VI20152020009: Cílený aplikovaný výzkum nových moderních technologií, metod a postupů ke zvýšení úrovně schopností HZS ČR - CAVHZS</a><br>

  • Návaznosti

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Ostatní

  • Rok uplatnění

    2019

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název statě ve sborníku

    Transport Means 2019 - Proceedings of the 23rd International Scientific Conference

  • ISBN

  • ISSN

    1822-296X

  • e-ISSN

    2351-7034

  • Počet stran výsledku

    6

  • Strana od-do

    435 - 440

  • Název nakladatele

    Kaunas University of Technology

  • Místo vydání

    Kaunas, Lithuania

  • Místo konání akce

    Palanga, Lithuania

  • Datum konání akce

    2. 10. 2019

  • Typ akce podle státní příslušnosti

    WRD - Celosvětová akce

  • Kód UT WoS článku