Design of multiplexer for electrical impedance tomography
Popis výsledku v původním jazyce
Electrical impedance tomography is a relatively new method in the field of structural health monitoring and non-destructive testing area. The electrical resistance tomography is a non-intrusive method enabling mapping of the spatial distribution of electrical conductivity of the monitored object. This paper describes the development of the multiplexer, which is one of the essential parts of the impedance tomography system. Frequency bandwidth, off isolation, and channel-to-channel cross talks are verified in the supposed frequency range. Basic multiplexer functionality is demonstrated on an image reconstruction of a carbon fiber reinforced polymer composite coupon damaged by an impact.
Název v anglickém jazyce
Design of multiplexer for electrical impedance tomography
Popis výsledku anglicky
Electrical impedance tomography is a relatively new method in the field of structural health monitoring and non-destructive testing area. The electrical resistance tomography is a non-intrusive method enabling mapping of the spatial distribution of electrical conductivity of the monitored object. This paper describes the development of the multiplexer, which is one of the essential parts of the impedance tomography system. Frequency bandwidth, off isolation, and channel-to-channel cross talks are verified in the supposed frequency range. Basic multiplexer functionality is demonstrated on an image reconstruction of a carbon fiber reinforced polymer composite coupon damaged by an impact.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Materials Today: Proceedings, Volume 4, Issue 5
ISBN
—
ISSN
2214-7853
e-ISSN
—
Počet stran výsledku
6
Strana od-do
5755-5760
Název nakladatele
Elsevier, Ltd
Místo vydání
Neuveden
Místo konání akce
Portorož, Slovinsko
Datum konání akce
20. 9. 2016
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000416470400003