X-ray testing of the multifoil optical system REX II for rocket experiment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00010669%3A_____%2F21%3AN0000037" target="_blank" >RIV/00010669:_____/21:N0000037 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/21:00352294 RIV/68407700:21340/21:00352294
Výsledek na webu
<a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11776/1177608/X-ray-testing-of-the-multifoil" target="_blank" >https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11776/1177608/X-ray-testing-of-the-multifoil</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2593763" target="_blank" >10.1117/12.2593763</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
X-ray testing of the multifoil optical system REX II for rocket experiment
Popis výsledku v původním jazyce
This paper presents the 2nd generation of the optical system for Rocket Experiment (REX2). This optical device is based on successful mission REX1. The purpose of REX2 is to verify X-ray optical system consisting of wide- field 2D X-ray Lobster-Eye (LE) optics with an uncooled Quad Timepix3 detector (512x512 px @ 55 um and spectrometer (active area 7 mm2, 145 eV @ 5.9 keV). The 2D Xray Lobster-Eye (LE) optics is a combination of two one-dimension LE modules with a focal length of up to 1 m and a FOV better than 4.0 x 4.0 deg. The proposed optical system has imaging capabilities (2.5 to 30 keV) and spectroscopy capabilities (0.2 to 10 keV). The optical system was recently tested in the X-ray vacuum chamber. The preliminary test results are presented and discussed in this paper.
Název v anglickém jazyce
X-ray testing of the multifoil optical system REX II for rocket experiment
Popis výsledku anglicky
This paper presents the 2nd generation of the optical system for Rocket Experiment (REX2). This optical device is based on successful mission REX1. The purpose of REX2 is to verify X-ray optical system consisting of wide- field 2D X-ray Lobster-Eye (LE) optics with an uncooled Quad Timepix3 detector (512x512 px @ 55 um and spectrometer (active area 7 mm2, 145 eV @ 5.9 keV). The 2D Xray Lobster-Eye (LE) optics is a combination of two one-dimension LE modules with a focal length of up to 1 m and a FOV better than 4.0 x 4.0 deg. The proposed optical system has imaging capabilities (2.5 to 30 keV) and spectroscopy capabilities (0.2 to 10 keV). The optical system was recently tested in the X-ray vacuum chamber. The preliminary test results are presented and discussed in this paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10308 - Astronomy (including astrophysics,space science)
Návaznosti výsledku
Projekt
<a href="/cs/project/LTAUSA18094" target="_blank" >LTAUSA18094: Studium detekce a zobrazování zdrojů rtg. záření pro astrofyziku</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
SPIE
ISBN
978-151064386-4
ISSN
0277786X
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
Proceedings of SPIE
Místo vydání
online
Místo konání akce
2021-04-19
Datum konání akce
1. 1. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—