Bacterial filtration efficiency of medical face masks – evaluation of the use of disposable plastic Petri dishes in Andersen impactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00013251%3A_____%2F23%3AN0000001" target="_blank" >RIV/00013251:_____/23:N0000001 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0167701222002500" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0167701222002500</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.mimet.2022.106655" target="_blank" >10.1016/j.mimet.2022.106655</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bacterial filtration efficiency of medical face masks – evaluation of the use of disposable plastic Petri dishes in Andersen impactor
Popis výsledku v původním jazyce
Bacterial filtration efficiency is the main characteristic of medical face masks effectivity and quality. The testing method is given by European and US, respectively, standard. The method is based on the analysis of biological aerosol with the bacterium Staphylococcus aureus in Andersen cascade impactor. The Andersen impactor contains six stages simulating the different parts of the respiratory tract, from the upper part with the larger droplets to the lungs with the small aerosol particles of the submicron size. The particles are separated depending on the size and sediment on agar medium in Petri dishes filled in the impactor. The use of the glass Petri dishes is recommended for the Andersen impactor, but the most of laboratories prefer the disposable plastic dishes, actually. The evaluation of the use of plastic dishes in Andersen impactor for the determination of the bacterial filtration efficiency of the medical face masks is the aim of this study.
Název v anglickém jazyce
Bacterial filtration efficiency of medical face masks – evaluation of the use of disposable plastic Petri dishes in Andersen impactor
Popis výsledku anglicky
Bacterial filtration efficiency is the main characteristic of medical face masks effectivity and quality. The testing method is given by European and US, respectively, standard. The method is based on the analysis of biological aerosol with the bacterium Staphylococcus aureus in Andersen cascade impactor. The Andersen impactor contains six stages simulating the different parts of the respiratory tract, from the upper part with the larger droplets to the lungs with the small aerosol particles of the submicron size. The particles are separated depending on the size and sediment on agar medium in Petri dishes filled in the impactor. The use of the glass Petri dishes is recommended for the Andersen impactor, but the most of laboratories prefer the disposable plastic dishes, actually. The evaluation of the use of plastic dishes in Andersen impactor for the determination of the bacterial filtration efficiency of the medical face masks is the aim of this study.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10606 - Microbiology
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Microbiological Methods
ISSN
0167-7012
e-ISSN
1872-8359
Svazek periodika
—
Číslo periodika v rámci svazku
204
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000904404500020
EID výsledku v databázi Scopus
—