Comparison of constructed wetland treatment efficiency in climatic conditions of the Czech Republic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00020711%3A_____%2F10%3A00003003" target="_blank" >RIV/00020711:_____/10:00003003 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of constructed wetland treatment efficiency in climatic conditions of the Czech Republic
Popis výsledku v původním jazyce
The aim of the study is to compare constructed wetland treatment efficiency during vegetation and non-vegetation period. Horizontal-flow constructed wetlands are advanced type of extensive technologies in the Czech Republic especially in municipalities under 500 PE. Treatment processes of these extensive technologies are significantly affected by external conditions as wastewater temperature, air temperature or vegetation occurrence. Altogether six constructed wetlands size of 100 to 800 PE were monitored and evaluated, including hydraulic load assessment. Average annual treatment efficiency range from 80,0 % to 98,2 % for suspended solids (SS), from 59,4 % to 88,5 % for COD, from 86,5 % to 93,0 % for BOD5 and from -16,1 % to 65,1 % for NH4-N. Different treatment efficiency in vegetation and non-vegetation period is exhibited by unstable NH4-N elimination whereas variation of organic pollution elimination is not so significant.
Název v anglickém jazyce
Comparison of constructed wetland treatment efficiency in climatic conditions of the Czech Republic
Popis výsledku anglicky
The aim of the study is to compare constructed wetland treatment efficiency during vegetation and non-vegetation period. Horizontal-flow constructed wetlands are advanced type of extensive technologies in the Czech Republic especially in municipalities under 500 PE. Treatment processes of these extensive technologies are significantly affected by external conditions as wastewater temperature, air temperature or vegetation occurrence. Altogether six constructed wetlands size of 100 to 800 PE were monitored and evaluated, including hydraulic load assessment. Average annual treatment efficiency range from 80,0 % to 98,2 % for suspended solids (SS), from 59,4 % to 88,5 % for COD, from 86,5 % to 93,0 % for BOD5 and from -16,1 % to 65,1 % for NH4-N. Different treatment efficiency in vegetation and non-vegetation period is exhibited by unstable NH4-N elimination whereas variation of organic pollution elimination is not so significant.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
12th IWA International Conference on Wetland Systems for Water Pollution Control, Volume II
ISBN
978-88-6060-300-5
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Palombi Editori
Místo vydání
San Giovanni Valdarno, Italy
Místo konání akce
Venice, Italy
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—