Microbial contamination and testing methods of hygienization of small wastewater treatment plant outflows for wastewater re-use
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00020711%3A_____%2F18%3A00004795" target="_blank" >RIV/00020711:_____/18:00004795 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Microbial contamination and testing methods of hygienization of small wastewater treatment plant outflows for wastewater re-use
Popis výsledku v původním jazyce
The aim of this paper is to present results of experimental and semi-operated hygienization of wastewater outflows with the mail goal what is wastewater re-use, especially for irrigation. Selected treatment plants included septics, plants using aerobic and anaerobic processes, vertical flow biofilters and extensive wastewater treatment plants (with horizontal and vertical subsurface flow reed-beds and stabilization ponds). In the period 2012-2017 were sampled inflows and outflows of the WWTPs with regard to microbial contamination indicators (thermotolerant coliform bacteria, E. coli, Enterococci). For the hygienization step of wastewater treatment were selected these methods: filtration (water flowed through vertical filters with specific filtration materials included zeolites, sand and artificial fillings), selected UV radiation equipment, chemical processes (oxidation) and membrane technology. Achieved results showed potential of tested methods for wastewater final purification.
Název v anglickém jazyce
Microbial contamination and testing methods of hygienization of small wastewater treatment plant outflows for wastewater re-use
Popis výsledku anglicky
The aim of this paper is to present results of experimental and semi-operated hygienization of wastewater outflows with the mail goal what is wastewater re-use, especially for irrigation. Selected treatment plants included septics, plants using aerobic and anaerobic processes, vertical flow biofilters and extensive wastewater treatment plants (with horizontal and vertical subsurface flow reed-beds and stabilization ponds). In the period 2012-2017 were sampled inflows and outflows of the WWTPs with regard to microbial contamination indicators (thermotolerant coliform bacteria, E. coli, Enterococci). For the hygienization step of wastewater treatment were selected these methods: filtration (water flowed through vertical filters with specific filtration materials included zeolites, sand and artificial fillings), selected UV radiation equipment, chemical processes (oxidation) and membrane technology. Achieved results showed potential of tested methods for wastewater final purification.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10503 - Water resources
Návaznosti výsledku
Projekt
<a href="/cs/project/TH02030583" target="_blank" >TH02030583: Optimalizace automatických závlahových systémů pro využití přečištěných odpadních vod - opatření pro snižování rizik sucha a eutrofizace povrchových zdrojů vody</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
4th IWA Specialized International Conference (ecoSTP 2018) – Ecotechnologies for Wastewater Treatment. Conference Proceeding.
ISBN
—
ISSN
neni
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
Western University
Místo vydání
London, Ontario, Kanada
Místo konání akce
London, Ontario, Kanada
Datum konání akce
25. 6. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—