Chybové obrazy pro spectroskopické zobrazování pomocí LCModelu s Cramer-Rao bounds
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F06%3A00000657" target="_blank" >RIV/00023001:_____/06:00000657 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Error images for spectroscopic imaging by LCModel using Cramer-Rao bounds
Popis výsledku v původním jazyce
The results of spectroscopic imaging (SI) measurements are often presented as metabolic images. If the spectra quality is not sufficient, the calculated concentrations are biased and the metabolic images show an incorrect metabolite distribution. To simplify the quality analysis of spectra measured by SI, an error image, reflecting the accuracy of the computed concentrations, can be displayed along with the metabolite image. In this paper the relevance of Cramer-Rao bounds (CRBs) calculated by the LCModel program to describe errors in estimated concentrations is validated using spectra simulations. The relation between the average CRBs and standard deviations (STD) of metabolite concentrations from 100 simulated spectra for various SNR and line broadening conditions is evaluated. A parameter for calculating error images for metabolite ratios is proposed and an effective way to display error images is shown. The results suggest that the average CRBs are strongly correlated with the stan
Název v anglickém jazyce
Error images for spectroscopic imaging by LCModel using Cramer-Rao bounds
Popis výsledku anglicky
The results of spectroscopic imaging (SI) measurements are often presented as metabolic images. If the spectra quality is not sufficient, the calculated concentrations are biased and the metabolic images show an incorrect metabolite distribution. To simplify the quality analysis of spectra measured by SI, an error image, reflecting the accuracy of the computed concentrations, can be displayed along with the metabolite image. In this paper the relevance of Cramer-Rao bounds (CRBs) calculated by the LCModel program to describe errors in estimated concentrations is validated using spectra simulations. The relation between the average CRBs and standard deviations (STD) of metabolite concentrations from 100 simulated spectra for various SNR and line broadening conditions is evaluated. A parameter for calculating error images for metabolite ratios is proposed and an effective way to display error images is shown. The results suggest that the average CRBs are strongly correlated with the stan
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA309%2F04%2F0753" target="_blank" >GA309/04/0753: Difúzní parametry extracelulárního prostoru v lidských gliomech</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Magnetic resonance materials in physics, biology and medicine
ISSN
0968-5243
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
14
Strana od-do
1-14
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—