Rychlé 3D mapování RF pole s použitím echo-planar imaging techniky
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F06%3A00000665" target="_blank" >RIV/00023001:_____/06:00000665 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fast 3D radiofrequency field mapping using echo-planar imaging
Popis výsledku v původním jazyce
An inhomogeneous radiofrequency (RF) magnetic field is an essential source of error for the quantification of MRI and MRS parameters. To correct for effects of RF inhomogeneities in 3D data sets, it is necessary to have knowledge of the 3D RF distribution in the sample. In this paper a method for fast 3D RF mapping is presented. The method is based on the simultaneous acquisition of a spin echo (SE) and a stimulated echo (STE) using echo-planar imaging (EPI). The acquisition of the 3D RF map using 64 partitions and TR = 500 ms requires 1.5 min. The use of the sequence in vivo is demonstrated by the calculation of the RF maps in the human brain at 3T. The comparison of calculated flip angles with the flip angles obtained by fitting signal behavior in the 3D stimulated-echo acquisition mode (STEAM)-EPI sequence and the analysis of errors due to spatially dependent T(1) values in the brain show that the accuracy of the calculated flip angles in the human brain is about 2 degrees.
Název v anglickém jazyce
Fast 3D radiofrequency field mapping using echo-planar imaging
Popis výsledku anglicky
An inhomogeneous radiofrequency (RF) magnetic field is an essential source of error for the quantification of MRI and MRS parameters. To correct for effects of RF inhomogeneities in 3D data sets, it is necessary to have knowledge of the 3D RF distribution in the sample. In this paper a method for fast 3D RF mapping is presented. The method is based on the simultaneous acquisition of a spin echo (SE) and a stimulated echo (STE) using echo-planar imaging (EPI). The acquisition of the 3D RF map using 64 partitions and TR = 500 ms requires 1.5 min. The use of the sequence in vivo is demonstrated by the calculation of the RF maps in the human brain at 3T. The comparison of calculated flip angles with the flip angles obtained by fitting signal behavior in the 3D stimulated-echo acquisition mode (STEAM)-EPI sequence and the analysis of errors due to spatially dependent T(1) values in the brain show that the accuracy of the calculated flip angles in the human brain is about 2 degrees.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC554" target="_blank" >LC554: Centrum neurověd</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Magnetic resonance in medicine
ISSN
0740-3194
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
1375-1379
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—