We present the case of a 77-year-old male patient who had undergone a bilateral venous aortorenal bypass graft 30 years previously. Thirteen years previously, the patient was shown to have a decrease in renal function, with mild shrinking of both kidneys; additionally, a stenosis was found in the left proximal anastomosis. At the most recent follow-up visit (1 year previously), ultrasound revealed an aneurysm (42 mm in diameter) of the left renal bypass graft; the finding was confirmed by CT angiography. A significant ostial stenosis of the left renal bypass graft was also confirmed. It was decided to place a self-expandable stent-graft into the aneurysm while also attempting to dilate the stenosis. Proximal endoleak after stent-graft placement necessitated the implantation of another, balloon-expandable stent-graft into the bypass graft ostium. Postprocedural angiography and follow-up by CT angiography at 3 months confirmed good patency of the stent-grafts and complete thrombosis of t
Název v anglickém jazyce
Treatment of venous aortorenal bypass graft aneurysm using a stent-graft
Popis výsledku anglicky
We present the case of a 77-year-old male patient who had undergone a bilateral venous aortorenal bypass graft 30 years previously. Thirteen years previously, the patient was shown to have a decrease in renal function, with mild shrinking of both kidneys; additionally, a stenosis was found in the left proximal anastomosis. At the most recent follow-up visit (1 year previously), ultrasound revealed an aneurysm (42 mm in diameter) of the left renal bypass graft; the finding was confirmed by CT angiography. A significant ostial stenosis of the left renal bypass graft was also confirmed. It was decided to place a self-expandable stent-graft into the aneurysm while also attempting to dilate the stenosis. Proximal endoleak after stent-graft placement necessitated the implantation of another, balloon-expandable stent-graft into the bypass graft ostium. Postprocedural angiography and follow-up by CT angiography at 3 months confirmed good patency of the stent-grafts and complete thrombosis of t
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cardiovascular and Interventional Radiology
ISSN
0174-1551
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000274314600027
EID výsledku v databázi Scopus
—