Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular Levitronix CentriMag system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F10%3A00002406" target="_blank" >RIV/00023001:_____/10:00002406 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular Levitronix CentriMag system
Popis výsledku v původním jazyce
The use of short-term mechanical circulatory support during postcardiotomy acute heart failure provides an opportunity to stabilize the patient's hemodynamic state while determining the best long-term strategy. Because all of these devices require anticoagulation treatment of various intensities, management of major bleeding can be critical for the overall outcome of the therapy. In this regard, the newest generation of magnetically levitated centrifugal-flow pumps affords several potential advantages in terms of thrombogenicity and eventual discontinuation of anticoagulation treatment. We report the use of a short-term biventricular assist device (Levitronix CentriMag) for 94 days in a 55-year-old man with refractory ventricular arrhythmias after combined heart surgery. Despite serious complications while the patient was on the assist device, including severe intestinal bleeding with the necessity of discontinuing anticoagulation for 10 days and, ultimately, hemicolectomy, the circula
Název v anglickém jazyce
Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular Levitronix CentriMag system
Popis výsledku anglicky
The use of short-term mechanical circulatory support during postcardiotomy acute heart failure provides an opportunity to stabilize the patient's hemodynamic state while determining the best long-term strategy. Because all of these devices require anticoagulation treatment of various intensities, management of major bleeding can be critical for the overall outcome of the therapy. In this regard, the newest generation of magnetically levitated centrifugal-flow pumps affords several potential advantages in terms of thrombogenicity and eventual discontinuation of anticoagulation treatment. We report the use of a short-term biventricular assist device (Levitronix CentriMag) for 94 days in a 55-year-old man with refractory ventricular arrhythmias after combined heart surgery. Despite serious complications while the patient was on the assist device, including severe intestinal bleeding with the necessity of discontinuing anticoagulation for 10 days and, ultimately, hemicolectomy, the circula
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0510" target="_blank" >1M0510: Centrum výzkumu chorob srdce a cév</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heart surgery forum
ISSN
1098-3511
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
—
Kód UT WoS článku
000285694400015
EID výsledku v databázi Scopus
—