The hemodynamic effect of right ventricle (RV), RT3DE targeted left Ventricle (LV) and Biventricular (BIV) pacing in the early postoperative period after cardiac surgery
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F11%3A00002417" target="_blank" >RIV/00023001:_____/11:00002417 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/11:10112469 RIV/00669806:_____/11:10112469
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The hemodynamic effect of right ventricle (RV), RT3DE targeted left Ventricle (LV) and Biventricular (BIV) pacing in the early postoperative period after cardiac surgery
Popis výsledku v původním jazyce
Background: Congestive heart failure negatively impacts the prognosis in patients after cardiac surgery. The aim of our study was to assess the value of targeted cardiac resynchronization therapy (CRT) within 72 hours after cardiac surgery in patients with mechanical dyssynchrony, who had an ejection fraction <= 35%, QRS >=150 ms or between 120 and 150 ms. Methods: A prospective randomized trial based on three-dimensional echocardiography (RT3DE) and optimized sequential dual-chamber (DDD ) pacing in patients after cardiac surgery. DDD epicardial pacing (Medtronic coaxial epicardial leads 6495) was provided by a modified Medtronic INSYNC III Pacemaker (Medtronic Inc., Minneapolis, MN, USA). Summary of results: The study included 21 patients with ischemic heart disease (HD) or valvular HD (16 men, 5 women, average age 69 years) with left ventricle (LV) dysfunction after cardiac surgery . Patients with biventricular (BIV) (CO 6.7 ? 1.7 L/min, CI 3.5 ? 0.8 L/min/m(2) ) and LV (CO 6.2 ? 1.
Název v anglickém jazyce
The hemodynamic effect of right ventricle (RV), RT3DE targeted left Ventricle (LV) and Biventricular (BIV) pacing in the early postoperative period after cardiac surgery
Popis výsledku anglicky
Background: Congestive heart failure negatively impacts the prognosis in patients after cardiac surgery. The aim of our study was to assess the value of targeted cardiac resynchronization therapy (CRT) within 72 hours after cardiac surgery in patients with mechanical dyssynchrony, who had an ejection fraction <= 35%, QRS >=150 ms or between 120 and 150 ms. Methods: A prospective randomized trial based on three-dimensional echocardiography (RT3DE) and optimized sequential dual-chamber (DDD ) pacing in patients after cardiac surgery. DDD epicardial pacing (Medtronic coaxial epicardial leads 6495) was provided by a modified Medtronic INSYNC III Pacemaker (Medtronic Inc., Minneapolis, MN, USA). Summary of results: The study included 21 patients with ischemic heart disease (HD) or valvular HD (16 men, 5 women, average age 69 years) with left ventricle (LV) dysfunction after cardiac surgery . Patients with biventricular (BIV) (CO 6.7 ? 1.7 L/min, CI 3.5 ? 0.8 L/min/m(2) ) and LV (CO 6.2 ? 1.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR9384" target="_blank" >NR9384: Resynchronizační léčba v časném období po kardiochirurgických operacích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Pacing and Clinical Electrophysiology
ISSN
0147-8389
e-ISSN
—
Svazek periodika
34
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—