Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: Midterm efficacy and predictors of postablation arrhythmia recurrences
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F11%3A00002452" target="_blank" >RIV/00023001:_____/11:00002452 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1111/j.1540-8167.2010.01942.x" target="_blank" >http://dx.doi.org/10.1111/j.1540-8167.2010.01942.x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/j.1540-8167.2010.01942.x" target="_blank" >10.1111/j.1540-8167.2010.01942.x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: Midterm efficacy and predictors of postablation arrhythmia recurrences
Popis výsledku v původním jazyce
Introduction: Remote navigation systems represent a novel strategy for catheter ablation of atrial fibrillation (AF). The goal of this study is to describe a single-center experience with the electromechanical robotic system (Sensei, Hansen Medical) in treatment of patients with paroxysmal AF. Methods: Out of 200 patients who underwent robotically guided ablation for AF between 2007 and 2009 at our institute, 100 patients (29 women, age 56.5 +/- 10 years) had paroxysmal AF refractory to antiarrhythmic drugs. Electroanatomic mapping using NavX system (St. Jude Medical) provided anatomical shell for subsequent circumferential ablation with robotic catheter (Artisan) loaded with a 3.5-mm, open-irrigation, cooled-tip ablation catheter. Results: A mean of 69 radiofrequency current applications (duration 2082 +/- 812 seconds) were delivered to achieve circumferential electrical isolation of pulmonary venous antra. Total procedural time reached 222 +/- 54 minutes. The mean fluoroscopic time w
Název v anglickém jazyce
Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: Midterm efficacy and predictors of postablation arrhythmia recurrences
Popis výsledku anglicky
Introduction: Remote navigation systems represent a novel strategy for catheter ablation of atrial fibrillation (AF). The goal of this study is to describe a single-center experience with the electromechanical robotic system (Sensei, Hansen Medical) in treatment of patients with paroxysmal AF. Methods: Out of 200 patients who underwent robotically guided ablation for AF between 2007 and 2009 at our institute, 100 patients (29 women, age 56.5 +/- 10 years) had paroxysmal AF refractory to antiarrhythmic drugs. Electroanatomic mapping using NavX system (St. Jude Medical) provided anatomical shell for subsequent circumferential ablation with robotic catheter (Artisan) loaded with a 3.5-mm, open-irrigation, cooled-tip ablation catheter. Results: A mean of 69 radiofrequency current applications (duration 2082 +/- 812 seconds) were delivered to achieve circumferential electrical isolation of pulmonary venous antra. Total procedural time reached 222 +/- 54 minutes. The mean fluoroscopic time w
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of cardiovascular electrophysiology
ISSN
1045-3873
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
534-540
Kód UT WoS článku
000290490000007
EID výsledku v databázi Scopus
—