The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F12%3A00056072" target="_blank" >RIV/00023001:_____/12:00056072 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S1547527112007710" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1547527112007710</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.hrthm.2012.07.016" target="_blank" >10.1016/j.hrthm.2012.07.016</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study
Popis výsledku v původním jazyce
BACKGROUND The clinical efficacy of catheter ablation of paroxysmal atrial fibrillation (AF) remains limited by difficulty in achieving durable pulmonary vein isolation (PVI). Suboptimal catheter tip-to-tissue contact force (CF) during lesion delivery isbelieved to reduce clinical efficacy. OBJECTIVE To determine the relationship between catheter CF during irrigated catheter ablation for AF and clinical recurrences during follow-up. METHODS Thirty-two patients with paroxysmal AF underwent PVI by usinga radiofrequency ablation catheter with a CF sensor integrated at its tip, and they were followed for 12 months. The relationship between the CF and clinical outcomes was determined. RESULTS Acute PVI was achieved in 100% of the veins. Thirty-five percent (351 of 1017) of the applications were placed with an average CF of <10 g (low CF). All patients treated with an average CF of <10 g (5 of 5 patients) experienced recurrences, whereas 80% of the patients treated with an average CF of >2
Název v anglickém jazyce
The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study
Popis výsledku anglicky
BACKGROUND The clinical efficacy of catheter ablation of paroxysmal atrial fibrillation (AF) remains limited by difficulty in achieving durable pulmonary vein isolation (PVI). Suboptimal catheter tip-to-tissue contact force (CF) during lesion delivery isbelieved to reduce clinical efficacy. OBJECTIVE To determine the relationship between catheter CF during irrigated catheter ablation for AF and clinical recurrences during follow-up. METHODS Thirty-two patients with paroxysmal AF underwent PVI by usinga radiofrequency ablation catheter with a CF sensor integrated at its tip, and they were followed for 12 months. The relationship between the CF and clinical outcomes was determined. RESULTS Acute PVI was achieved in 100% of the veins. Thirty-five percent (351 of 1017) of the applications were placed with an average CF of <10 g (low CF). All patients treated with an average CF of <10 g (5 of 5 patients) experienced recurrences, whereas 80% of the patients treated with an average CF of >2
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heart Rhythm
ISSN
1547-5271
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
1789-1795
Kód UT WoS článku
000310532300011