Popis výsledku v původním jazyce
Expansion of indications to catheter ablation has led to a change of the paradigm from electrophysiologically guided procedure to a procedure guided predominantly anatomically. Accurate online identification of cardiac structures and catheters becomes mandatory and ICE is at present the only imaging modality that can accomplish easily this task. It is a valuable tool for guiding procedures such as transseptal puncture or for monitoring complex ablation procedures like ablation of atrial fibrillation orventricular tachycardias. It also allows prevention and/or early detection of intraprocedural complications. The widespread use of ICE is likely to result in reduction of fluoroscopy time and to maximize safety and efficacy of complex ablation procedures.
Název v anglickém jazyce
Intraprocedural techniques: transesophageal (2D/3D) and intracardiac echocardiography
Popis výsledku anglicky
Expansion of indications to catheter ablation has led to a change of the paradigm from electrophysiologically guided procedure to a procedure guided predominantly anatomically. Accurate online identification of cardiac structures and catheters becomes mandatory and ICE is at present the only imaging modality that can accomplish easily this task. It is a valuable tool for guiding procedures such as transseptal puncture or for monitoring complex ablation procedures like ablation of atrial fibrillation orventricular tachycardias. It also allows prevention and/or early detection of intraprocedural complications. The widespread use of ICE is likely to result in reduction of fluoroscopy time and to maximize safety and efficacy of complex ablation procedures.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Cardiac imaging in electrophysiology
ISBN
978-1-84882-485-0
Počet stran výsledku
16
Strana od-do
1-16
Počet stran knihy
328
Název nakladatele
Springer
Místo vydání
London