Multimodal imaging with hybrid semiconductor detectors Timepix for an experimental MRI-SPECT system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F13%3A00057910" target="_blank" >RIV/00023001:_____/13:00057910 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/13:00210426
Výsledek na webu
<a href="http://iopscience.iop.org/1748-0221/8/01/C01022/pdf/1748-0221_8_01_C01022.pdf" target="_blank" >http://iopscience.iop.org/1748-0221/8/01/C01022/pdf/1748-0221_8_01_C01022.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/8/01/C01022" target="_blank" >10.1088/1748-0221/8/01/C01022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Multimodal imaging with hybrid semiconductor detectors Timepix for an experimental MRI-SPECT system
Popis výsledku v původním jazyce
An increasing number of clinical applications are being based on multimodal imaging systems (MIS), including anatomical (CT, MRI) and functional (PET, SPECT) techniques to provide complex information in a single image. CT with one of the scintigraphic methods (PET or SPECT) is nowadays a combination of choice for clinical practice and it is mostly used in cardiography and tumour diagnostics. Combination with MRI is also being implemented as no radiation dose is imparted to the patient and it is possibleto gain higher structural resolution of soft tissues (brain imaging). A major disadvantage of such systems is inability to operate scintillators with photomultipliers (used for detection of g rays) in presence of high magnetic fields. In this work we present the application of the semiconductor pixel detector for SPECT method in combination with MR imaging. We propose a novel approach based on MRI compatible setup with CdTe pixel sensor Timepix and non-conductive collimator. Measurement
Název v anglickém jazyce
Multimodal imaging with hybrid semiconductor detectors Timepix for an experimental MRI-SPECT system
Popis výsledku anglicky
An increasing number of clinical applications are being based on multimodal imaging systems (MIS), including anatomical (CT, MRI) and functional (PET, SPECT) techniques to provide complex information in a single image. CT with one of the scintigraphic methods (PET or SPECT) is nowadays a combination of choice for clinical practice and it is mostly used in cardiography and tumour diagnostics. Combination with MRI is also being implemented as no radiation dose is imparted to the patient and it is possibleto gain higher structural resolution of soft tissues (brain imaging). A major disadvantage of such systems is inability to operate scintillators with photomultipliers (used for detection of g rays) in presence of high magnetic fields. In this work we present the application of the semiconductor pixel detector for SPECT method in combination with MR imaging. We propose a novel approach based on MRI compatible setup with CdTe pixel sensor Timepix and non-conductive collimator. Measurement
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010164" target="_blank" >TA01010164: Pokročilé techniky detekce ionizujícího záření</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
"C01022/1"-7
Kód UT WoS článku
000320665400022
EID výsledku v databázi Scopus
—