Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F13%3A00058780" target="_blank" >RIV/00023001:_____/13:00058780 - isvavai.cz</a>
Výsledek na webu
<a href="http://circep.ahajournals.org/content/6/3/467" target="_blank" >http://circep.ahajournals.org/content/6/3/467</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCEP.113.000431" target="_blank" >10.1161/CIRCEP.113.000431</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience
Popis výsledku v původním jazyce
Background Because of the technical difficulty with achieving pulmonary vein (PV) isolation in the treatment of patients with paroxysmal atrial fibrillation, novel catheter designs to facilitate the procedure are in development. A visually guided laser ablation (VGLA) catheter was designed to allow the operator to directly visualize target tissue for ablation and then deliver laser energy to perform point-to-point circumferential ablation. Single-center studies have demonstrated favorable safety and efficacy. We sought to determine the multicenter feasibility, efficacy, and safety of performing PV isolation using the VGLA catheter. Methods and Results This study includes the first 200 paroxysmal atrial fibrillation patients treated with the VGLA catheter (33 operators, 15 centers). After transseptal puncture, the VGLA catheter was used to perform PV isolation. Electric isolation was assessed using a circular mapping catheter. Using the VGLA catheter, 98.8% (95% confidence interval, 97.
Název v anglickém jazyce
Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience
Popis výsledku anglicky
Background Because of the technical difficulty with achieving pulmonary vein (PV) isolation in the treatment of patients with paroxysmal atrial fibrillation, novel catheter designs to facilitate the procedure are in development. A visually guided laser ablation (VGLA) catheter was designed to allow the operator to directly visualize target tissue for ablation and then deliver laser energy to perform point-to-point circumferential ablation. Single-center studies have demonstrated favorable safety and efficacy. We sought to determine the multicenter feasibility, efficacy, and safety of performing PV isolation using the VGLA catheter. Methods and Results This study includes the first 200 paroxysmal atrial fibrillation patients treated with the VGLA catheter (33 operators, 15 centers). After transseptal puncture, the VGLA catheter was used to perform PV isolation. Electric isolation was assessed using a circular mapping catheter. Using the VGLA catheter, 98.8% (95% confidence interval, 97.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Circulation-Arrhythmia and Electrophysiology
ISSN
1941-3149
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
467-472
Kód UT WoS článku
000320760200012
EID výsledku v databázi Scopus
—