The Effect of ICD Programming on Inappropriate and Appropriate ICD Therapies in Ischemic and Nonischemic Cardiomyopathy: The MADIT-RIT Trial
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F15%3A00059325" target="_blank" >RIV/00023001:_____/15:00059325 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1111/jce.12605/epdf" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1111/jce.12605/epdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jce.12605" target="_blank" >10.1111/jce.12605</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effect of ICD Programming on Inappropriate and Appropriate ICD Therapies in Ischemic and Nonischemic Cardiomyopathy: The MADIT-RIT Trial
Popis výsledku v původním jazyce
ICD Programming in Ischemic and Nonischemic Cardiomyopathy IntroductionThe MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. Methods and ResultsFirst and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. ConclusionHigh-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy.
Název v anglickém jazyce
The Effect of ICD Programming on Inappropriate and Appropriate ICD Therapies in Ischemic and Nonischemic Cardiomyopathy: The MADIT-RIT Trial
Popis výsledku anglicky
ICD Programming in Ischemic and Nonischemic Cardiomyopathy IntroductionThe MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. Methods and ResultsFirst and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. ConclusionHigh-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of cardiovascular electrophysiology
ISSN
1045-3873
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
424-433
Kód UT WoS článku
000352814300014
EID výsledku v databázi Scopus
—