Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F15%3A00059545" target="_blank" >RIV/00023001:_____/15:00059545 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.clinchem.org/content/61/10/1283" target="_blank" >http://www.clinchem.org/content/61/10/1283</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1373/clinchem.2015.242081" target="_blank" >10.1373/clinchem.2015.242081</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology
Popis výsledku v původním jazyce
BACKGROUND: The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report development and preliminary validation of an in-vestigational assay meeting these requirements and demonstrate its applicability to cohorts of healthy individuals and patients with heart failure. METHODS: On the basis of single molecule array technology, we developed a 45-min immunoassay for cardiac troponin I (cTnI) for use on a novel, fully automated digital analyzer. We characterized its analytical performance and measured cTnI in healthy individuals and heart failure patients in a preliminary study of assay analytical efficacy. RESULTS: The assay exhibited a limit of detection of 0.01 ng/L, a limit of quantification of 0.08 ng/L, and a total CV of 10% at 2.0 ng/L. cTnI concentrations were well above the assay limit of detection for all samples tested, including samples from healthy individuals. cTnI was significantly higher in heart failure patients, and exhibited increasing median and interquartile concentrations with increasing New York Heart Association classification of heart failure severity. CONCLUSIONS: The robust 2-log increase in sensitivity relative to contemporary high-sensitivity cardiac troponin immunoassays, combined with full automation, make this assay suitable for exploring cTnI concentrations in cohorts of healthy individuals and for the potential prognostic application of serial cardiac troponin measurements in both apparently healthy and diseased individuals. (C) 2015 American Association for Clinical Chemistry
Název v anglickém jazyce
Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology
Popis výsledku anglicky
BACKGROUND: The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report development and preliminary validation of an in-vestigational assay meeting these requirements and demonstrate its applicability to cohorts of healthy individuals and patients with heart failure. METHODS: On the basis of single molecule array technology, we developed a 45-min immunoassay for cardiac troponin I (cTnI) for use on a novel, fully automated digital analyzer. We characterized its analytical performance and measured cTnI in healthy individuals and heart failure patients in a preliminary study of assay analytical efficacy. RESULTS: The assay exhibited a limit of detection of 0.01 ng/L, a limit of quantification of 0.08 ng/L, and a total CV of 10% at 2.0 ng/L. cTnI concentrations were well above the assay limit of detection for all samples tested, including samples from healthy individuals. cTnI was significantly higher in heart failure patients, and exhibited increasing median and interquartile concentrations with increasing New York Heart Association classification of heart failure severity. CONCLUSIONS: The robust 2-log increase in sensitivity relative to contemporary high-sensitivity cardiac troponin immunoassays, combined with full automation, make this assay suitable for exploring cTnI concentrations in cohorts of healthy individuals and for the potential prognostic application of serial cardiac troponin measurements in both apparently healthy and diseased individuals. (C) 2015 American Association for Clinical Chemistry
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical chemistry
ISSN
0009-9147
e-ISSN
—
Svazek periodika
61
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
1283-1291
Kód UT WoS článku
000362692600013
EID výsledku v databázi Scopus
—