Bipolar radiofrequency catheter ablation for refractory perimitral flutter: a case report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F15%3A00059566" target="_blank" >RIV/00023001:_____/15:00059566 - isvavai.cz</a>
Výsledek na webu
<a href="http://bmccardiovascdisord.biomedcentral.com/articles/10.1186/s12872-015-0132-z" target="_blank" >http://bmccardiovascdisord.biomedcentral.com/articles/10.1186/s12872-015-0132-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12872-015-0132-z" target="_blank" >10.1186/s12872-015-0132-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bipolar radiofrequency catheter ablation for refractory perimitral flutter: a case report
Popis výsledku v původním jazyce
Background: Mitral isthmus is often targeted as a part of stepwise approach during radiofrequency ablation for persistent atrial ablation. Acute success rate in achieving the mitral isthmus block is only modest, late reconduction rate is relatively high and, consequently, incomplete lesion may be proarrhythmic. We describe the first-in-man experience with successful MI ablation by bipolar RF energy delivery. Case presentation: A 64-year-old caucasian man after two previous ablation procedures for drug resistant atrial fibrillation in recent four years, which included pulmonary vein isolation and linear left atrial lesions, was referred for the treatment of recurrent perimitral flutter. Despite the third attempt to create bidirectional block at the mitral isthmus region, we were not even able to stop the arrhythmia by aggressive unipolar radiofrequency ablation both from the left atrium and coronary sinus, because of deeply embedded slow conducting channel probably around the vein of Marshall. Arrhythmia was finally terminated and the block was achieved by bipolar radiofrequency ablation between two irrigated-tip catheters positioned at the left atrial endocardium and contralaterally inside the coronary sinus. Conclusion: Bipolar radiofrequency energy delivery can be an option for ablation of perimitral flutter resistant to standard unipolar radiofrequency ablation. This may improve clinical outcome of patients undergoing non-pharmacological treatment for persistent atrial fibrillation. The safety and efficacy of this technique has to be confirmed in future studies.
Název v anglickém jazyce
Bipolar radiofrequency catheter ablation for refractory perimitral flutter: a case report
Popis výsledku anglicky
Background: Mitral isthmus is often targeted as a part of stepwise approach during radiofrequency ablation for persistent atrial ablation. Acute success rate in achieving the mitral isthmus block is only modest, late reconduction rate is relatively high and, consequently, incomplete lesion may be proarrhythmic. We describe the first-in-man experience with successful MI ablation by bipolar RF energy delivery. Case presentation: A 64-year-old caucasian man after two previous ablation procedures for drug resistant atrial fibrillation in recent four years, which included pulmonary vein isolation and linear left atrial lesions, was referred for the treatment of recurrent perimitral flutter. Despite the third attempt to create bidirectional block at the mitral isthmus region, we were not even able to stop the arrhythmia by aggressive unipolar radiofrequency ablation both from the left atrium and coronary sinus, because of deeply embedded slow conducting channel probably around the vein of Marshall. Arrhythmia was finally terminated and the block was achieved by bipolar radiofrequency ablation between two irrigated-tip catheters positioned at the left atrial endocardium and contralaterally inside the coronary sinus. Conclusion: Bipolar radiofrequency energy delivery can be an option for ablation of perimitral flutter resistant to standard unipolar radiofrequency ablation. This may improve clinical outcome of patients undergoing non-pharmacological treatment for persistent atrial fibrillation. The safety and efficacy of this technique has to be confirmed in future studies.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BMC cardiovascular disorders
ISSN
1471-2261
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
Oct 28
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
"art ID 139"
Kód UT WoS článku
000363624400002
EID výsledku v databázi Scopus
—