Response by Netuka et al regarding the article 'Evaluation of low-intensity anticoagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study'
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F18%3A00077467" target="_blank" >RIV/00023001:_____/18:00077467 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.jhltonline.org/article/S1053-2498(18)31577-8/pdf" target="_blank" >https://www.jhltonline.org/article/S1053-2498(18)31577-8/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.healun.2018.07.017" target="_blank" >10.1016/j.healun.2018.07.017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Response by Netuka et al regarding the article 'Evaluation of low-intensity anticoagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study'
Popis výsledku v původním jazyce
Our investigation seeks to move the field forward toward the position that, when technology advances result in a reduction of thrombotic complications, it makes intuitive sense to begin to decrease the hazards that emanate from excessive anti-coagulation. The pivotal 2-year analysis of the MOMENTUM 3 trial demonstrated that the HeartMate 3 (HM3) left ventricular assist device is associated with absence of pump exchange due to pump thrombosis and a halving of the rate of stroke events. Our ongoing follow-up of cases within the MAGENTUM 1 population suggest preserved stability despite maintenance of low INR in the long-term phase, even beyond 1 year of support.
Název v anglickém jazyce
Response by Netuka et al regarding the article 'Evaluation of low-intensity anticoagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study'
Popis výsledku anglicky
Our investigation seeks to move the field forward toward the position that, when technology advances result in a reduction of thrombotic complications, it makes intuitive sense to begin to decrease the hazards that emanate from excessive anti-coagulation. The pivotal 2-year analysis of the MOMENTUM 3 trial demonstrated that the HeartMate 3 (HM3) left ventricular assist device is associated with absence of pump exchange due to pump thrombosis and a halving of the rate of stroke events. Our ongoing follow-up of cases within the MAGENTUM 1 population suggest preserved stability despite maintenance of low INR in the long-term phase, even beyond 1 year of support.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of heart and lung transplantation
ISSN
1053-2498
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
1279-1280
Kód UT WoS článku
000450568000015
EID výsledku v databázi Scopus
2-s2.0-85054422312