Comparison of two modes of long-term ECG monitoring to assess the efficacy of catheter ablation for paroxysmal atrial fibrillation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F19%3A00077657" target="_blank" >RIV/00023001:_____/19:00077657 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/65269705:_____/19:00070821
Výsledek na webu
<a href="http://biomed.papers.upol.cz/pdfs/bio/2019/01/07.pdf" target="_blank" >http://biomed.papers.upol.cz/pdfs/bio/2019/01/07.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2018.031" target="_blank" >10.5507/bp.2018.031</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of two modes of long-term ECG monitoring to assess the efficacy of catheter ablation for paroxysmal atrial fibrillation
Popis výsledku v původním jazyce
Aims. Optimal ECG monitoring in detecting recurrences of atrial fibrillation (AF) or atrial tachycardia (AT) after catheter ablation has not been well established. The purpose of this prospective study was to compare the utility of daily ECG monitoring with episodic card recorder (ECR) vs. periodic monitoring with episodic loop recorder (ELR) for the detection of post-blanking AF/AT recurrences during early (Months 4-6) and late (Months 7-12) periods after catheter ablation for paroxysmal AF. Methods. The study included 105 consecutive patients, who received ECR for 12 months and were instructed to send at least 2 random ECG recordings daily with extra-recordings during symptoms. The patients were simultaneously monitored for one week with ELR at the end of each period (Months 6 and 12). Results. Thirty-one and 12 patients with AF/AT recurrence were identified by means of ECR and ELR, respectively. In patients with complete and valid data, ELR technology was inferior to ECR by detecting AF/AT in 5 (31%) of 16 and 5 (26%) of 19 patients with arrhythmia identified by ECR in the early and late period, respectively. Overall, ELR had a sensitivity of 8/23 (35%) for detecting AF/AT recurrence.There was no single patient with AF/AT recurrence on ELR that would not be known from ECR monitoring. Only 2 patients with arrhythmia recurrence were completely asymptomatic throughout the study period. Conclusion. Daily ECG monitoring with ECR was better than periodic monitoring with ELR in detecting AF/AT recurrences during the follow-up periods. Entirely asymptomatic patients with AF/AT recurrences were rare
Název v anglickém jazyce
Comparison of two modes of long-term ECG monitoring to assess the efficacy of catheter ablation for paroxysmal atrial fibrillation
Popis výsledku anglicky
Aims. Optimal ECG monitoring in detecting recurrences of atrial fibrillation (AF) or atrial tachycardia (AT) after catheter ablation has not been well established. The purpose of this prospective study was to compare the utility of daily ECG monitoring with episodic card recorder (ECR) vs. periodic monitoring with episodic loop recorder (ELR) for the detection of post-blanking AF/AT recurrences during early (Months 4-6) and late (Months 7-12) periods after catheter ablation for paroxysmal AF. Methods. The study included 105 consecutive patients, who received ECR for 12 months and were instructed to send at least 2 random ECG recordings daily with extra-recordings during symptoms. The patients were simultaneously monitored for one week with ELR at the end of each period (Months 6 and 12). Results. Thirty-one and 12 patients with AF/AT recurrence were identified by means of ECR and ELR, respectively. In patients with complete and valid data, ELR technology was inferior to ECR by detecting AF/AT in 5 (31%) of 16 and 5 (26%) of 19 patients with arrhythmia identified by ECR in the early and late period, respectively. Overall, ELR had a sensitivity of 8/23 (35%) for detecting AF/AT recurrence.There was no single patient with AF/AT recurrence on ELR that would not be known from ECR monitoring. Only 2 patients with arrhythmia recurrence were completely asymptomatic throughout the study period. Conclusion. Daily ECG monitoring with ECR was better than periodic monitoring with ELR in detecting AF/AT recurrences during the follow-up periods. Entirely asymptomatic patients with AF/AT recurrences were rare
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical papers
ISSN
1213-8118
e-ISSN
—
Svazek periodika
163
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
54-60
Kód UT WoS článku
000458362500007
EID výsledku v databázi Scopus
2-s2.0-85062326184