The association of mechanical dyssynchrony and resynchronization therapy with survival in heart failure with a wide QRS complex: a two-world study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F20%3A00079920" target="_blank" >RIV/00023001:_____/20:00079920 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/content/pdf/10.1007/s10554-020-01865-x.pdf" target="_blank" >https://link.springer.com/content/pdf/10.1007/s10554-020-01865-x.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10554-020-01865-x" target="_blank" >10.1007/s10554-020-01865-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The association of mechanical dyssynchrony and resynchronization therapy with survival in heart failure with a wide QRS complex: a two-world study
Popis výsledku v původním jazyce
Setting up a randomized trial to assess the association of mechanical dyssynchrony (MD) and the success of cardiac resynchronization therapy (CRT) in heart failure with a wide QRS complex is ethically challenging. We therefore investigated this association in a retrospective cohort study observing different treatment strategies which were chosen based on the availability of health care resources. The survival of 500 patients from six Western European centers treated with CRT was compared to their 137 Eastern European counterparts not treated with CRT, with regard to the presence of MD. MD was visually assessed and was defined as the presence of apical rocking and/or septal flash. Patients were followed for a mean of 26 +/- 8 months for the occurrence of death of any cause. As compared with medical therapy alone, CRT was associated with a more favorable survival (hazard ratio (HR), 0.53; 95% confidence interval (CI) 0.35-0.79; P = 0.002). Patients with MD treated by CRT had better survival than patients belonging to all other groups-they showed 72%, 66% and 56% reduction in all-cause mortality, respectively, compared to patients with MD not treated by CRT (HR 0.28; 95% CI 0.17-0.44), patients without MD treated by CRT (HR 0.34; 95% CI 0.22-0.52) and patients without MD not treated by CRT (HR 0.44; 95% CI 0.25-0.76). Patients with wide QRS complex who are treated with CRT have a significantly better survival when MD is present.
Název v anglickém jazyce
The association of mechanical dyssynchrony and resynchronization therapy with survival in heart failure with a wide QRS complex: a two-world study
Popis výsledku anglicky
Setting up a randomized trial to assess the association of mechanical dyssynchrony (MD) and the success of cardiac resynchronization therapy (CRT) in heart failure with a wide QRS complex is ethically challenging. We therefore investigated this association in a retrospective cohort study observing different treatment strategies which were chosen based on the availability of health care resources. The survival of 500 patients from six Western European centers treated with CRT was compared to their 137 Eastern European counterparts not treated with CRT, with regard to the presence of MD. MD was visually assessed and was defined as the presence of apical rocking and/or septal flash. Patients were followed for a mean of 26 +/- 8 months for the occurrence of death of any cause. As compared with medical therapy alone, CRT was associated with a more favorable survival (hazard ratio (HR), 0.53; 95% confidence interval (CI) 0.35-0.79; P = 0.002). Patients with MD treated by CRT had better survival than patients belonging to all other groups-they showed 72%, 66% and 56% reduction in all-cause mortality, respectively, compared to patients with MD not treated by CRT (HR 0.28; 95% CI 0.17-0.44), patients without MD treated by CRT (HR 0.34; 95% CI 0.22-0.52) and patients without MD not treated by CRT (HR 0.44; 95% CI 0.25-0.76). Patients with wide QRS complex who are treated with CRT have a significantly better survival when MD is present.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International journal of cardiovascular imaging
ISSN
1569-5794
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
1507-1514
Kód UT WoS článku
000529854500001
EID výsledku v databázi Scopus
2-s2.0-85083964003