Double-balloon technique for retrograde venous ethanol ablation of ventricular arrhythmias in the absence of suitable intramural veins
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F20%3A00080523" target="_blank" >RIV/00023001:_____/20:00080523 - isvavai.cz</a>
Výsledek na webu
<a href="https://reader.elsevier.com/reader/sd/pii/S1547527120305233?token=F6077341DA637BC122FBDED61C1889B1404791AFC09B006446E373021172735318CF0569A3AB4D36088ECA2A566181CB" target="_blank" >https://reader.elsevier.com/reader/sd/pii/S1547527120305233?token=F6077341DA637BC122FBDED61C1889B1404791AFC09B006446E373021172735318CF0569A3AB4D36088ECA2A566181CB</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.hrthm.2020.05.027" target="_blank" >10.1016/j.hrthm.2020.05.027</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Double-balloon technique for retrograde venous ethanol ablation of ventricular arrhythmias in the absence of suitable intramural veins
Popis výsledku v původním jazyce
Background: Venous ethanol infusion via an occlusive balloon has been used as a bailout approach to treat ablation-refractory ventricular arrhythmias (VAs). Unfavorable venous anatomy (lack of intramural veins at the targeted site or collateral vein–ethanol shunting) limits its efficacy. Blocking collateral flow with a second balloon may optimize myocardial ethanol delivery. Objective: The purpose of this study was to validate the “double-balloon” approach to enhance ethanol delivery in cases of unfavorable venous anatomy. Methods: Eight patients referred after failed ablations (3 left ventricular [LV] summit, 5 scar-related ventricular tachycardia) underwent endocardial mapping and additional radiofrequency ablation without VA resolution. Coronary veins were mapped using a multipolar catheter or wire, and selective venograms were obtained. The double balloon was used when (1) distal collateral branches shunted flow away from the targeted region; (2) the target vein had optimal signals only proximally; or (3) a large vein was targeted that had multiple branches for a large area of interest. Results: Acute successful ethanol infusion myocardial delivery and resolution of VA was accomplished using the posterolateral LV veins (n = 2 patients, 3 procedures), lateral LV vein (n = 1), apical anterior interventricular vein (AIV; n = 1), middle cardiac vein (n = 1), and septal branches of the AIV (n = 3). At median follow-up of 313.5 days, 2 patients experienced recurrence. Conclusion: The double-balloon technique can enhance ethanol delivery to target isolated vein segments, block collateral flow, or target extensive areas, and can expand the utility of venous ethanol for treatment of VAs. © 2020 Heart Rhythm Society
Název v anglickém jazyce
Double-balloon technique for retrograde venous ethanol ablation of ventricular arrhythmias in the absence of suitable intramural veins
Popis výsledku anglicky
Background: Venous ethanol infusion via an occlusive balloon has been used as a bailout approach to treat ablation-refractory ventricular arrhythmias (VAs). Unfavorable venous anatomy (lack of intramural veins at the targeted site or collateral vein–ethanol shunting) limits its efficacy. Blocking collateral flow with a second balloon may optimize myocardial ethanol delivery. Objective: The purpose of this study was to validate the “double-balloon” approach to enhance ethanol delivery in cases of unfavorable venous anatomy. Methods: Eight patients referred after failed ablations (3 left ventricular [LV] summit, 5 scar-related ventricular tachycardia) underwent endocardial mapping and additional radiofrequency ablation without VA resolution. Coronary veins were mapped using a multipolar catheter or wire, and selective venograms were obtained. The double balloon was used when (1) distal collateral branches shunted flow away from the targeted region; (2) the target vein had optimal signals only proximally; or (3) a large vein was targeted that had multiple branches for a large area of interest. Results: Acute successful ethanol infusion myocardial delivery and resolution of VA was accomplished using the posterolateral LV veins (n = 2 patients, 3 procedures), lateral LV vein (n = 1), apical anterior interventricular vein (AIV; n = 1), middle cardiac vein (n = 1), and septal branches of the AIV (n = 3). At median follow-up of 313.5 days, 2 patients experienced recurrence. Conclusion: The double-balloon technique can enhance ethanol delivery to target isolated vein segments, block collateral flow, or target extensive areas, and can expand the utility of venous ethanol for treatment of VAs. © 2020 Heart Rhythm Society
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Heart rhythm
ISSN
1547-5271
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
2126-2134
Kód UT WoS článku
000594819400015
EID výsledku v databázi Scopus
2-s2.0-85096098516