Magnetic resonance tractography of the lumbosacral plexus: Step-by-step
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F21%3A00080949" target="_blank" >RIV/00023001:_____/21:00080949 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/21:10428846
Výsledek na webu
<a href="https://journals.lww.com/md-journal/Fulltext/2021/02120/Magnetic_resonance_tractography_of_the_lumbosacral.83.aspx" target="_blank" >https://journals.lww.com/md-journal/Fulltext/2021/02120/Magnetic_resonance_tractography_of_the_lumbosacral.83.aspx</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/MD.0000000000024646" target="_blank" >10.1097/MD.0000000000024646</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Magnetic resonance tractography of the lumbosacral plexus: Step-by-step
Popis výsledku v původním jazyce
ABSTRACT: MR tractography of the lumbosacral plexus (LSP) is challenging due to the difficulty of acquiring high quality data and accurately estimating the neuronal tracts. We proposed an algorithm for an accurate visualization and assessment of the major LSP bundles using the segmentation of the cauda equina as seed points for the initial starting area for the fiber tracking algorithm.Twenty-six healthy volunteers underwent MRI examinations on a 3T MR scanner using the phased array coils with optimized measurement protocols for diffusion-weighted images and coronal T2 weighted 3D short-term inversion recovery sampling perfection with application optimized contrast using varying flip angle evaluation sequences used for LSP fiber reconstruction and MR neurography (MRN).The fiber bundles reconstruction was optimized in terms of eliminating the muscle fibers contamination using the segmentation of cauda equina, the effects of the normalized quantitative anisotropy (NQA) and angular threshold on reconstruction of the LSP. In this study, the NQA parameter has been used for fiber tracking instead of fractional anisotropy (FA) and the regions of interest positioning was precisely adjusted bilaterally and symmetrically in each individual subject.The diffusion data were processed in individual L3-S2 nerve fibers using the generalized Q-sampling imaging algorithm. Data (mean FA, mean diffusivity, axial diffusivity and radial diffusivity, and normalized quantitative anisotropy) were statistically analyzed using the linear mixed-effects model. The MR neurography was performed in MedINRIA and post-processed using the maximum intensity projection method to demonstrate LSP tracts in multiple planes.FA values significantly decreased towards the sacral region (P < .001); by contrast, mean diffusivity, axial diffusivity, radial diffusivity and NQA values significantly increased towards the sacral region (P < .001).Fiber tractography of the LSP was feasible in all examined subjects and closely corresponded with the nerves visible in the maximum intensity projection images of MR neurography. Usage of NQA instead of FA in the proposed algorithm enabled better separation of muscle and nerve fibers.The presented algorithm yields a high quality reconstruction of the LSP bundles that may be helpful both in research and clinical practice. Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc.
Název v anglickém jazyce
Magnetic resonance tractography of the lumbosacral plexus: Step-by-step
Popis výsledku anglicky
ABSTRACT: MR tractography of the lumbosacral plexus (LSP) is challenging due to the difficulty of acquiring high quality data and accurately estimating the neuronal tracts. We proposed an algorithm for an accurate visualization and assessment of the major LSP bundles using the segmentation of the cauda equina as seed points for the initial starting area for the fiber tracking algorithm.Twenty-six healthy volunteers underwent MRI examinations on a 3T MR scanner using the phased array coils with optimized measurement protocols for diffusion-weighted images and coronal T2 weighted 3D short-term inversion recovery sampling perfection with application optimized contrast using varying flip angle evaluation sequences used for LSP fiber reconstruction and MR neurography (MRN).The fiber bundles reconstruction was optimized in terms of eliminating the muscle fibers contamination using the segmentation of cauda equina, the effects of the normalized quantitative anisotropy (NQA) and angular threshold on reconstruction of the LSP. In this study, the NQA parameter has been used for fiber tracking instead of fractional anisotropy (FA) and the regions of interest positioning was precisely adjusted bilaterally and symmetrically in each individual subject.The diffusion data were processed in individual L3-S2 nerve fibers using the generalized Q-sampling imaging algorithm. Data (mean FA, mean diffusivity, axial diffusivity and radial diffusivity, and normalized quantitative anisotropy) were statistically analyzed using the linear mixed-effects model. The MR neurography was performed in MedINRIA and post-processed using the maximum intensity projection method to demonstrate LSP tracts in multiple planes.FA values significantly decreased towards the sacral region (P < .001); by contrast, mean diffusivity, axial diffusivity, radial diffusivity and NQA values significantly increased towards the sacral region (P < .001).Fiber tractography of the LSP was feasible in all examined subjects and closely corresponded with the nerves visible in the maximum intensity projection images of MR neurography. Usage of NQA instead of FA in the proposed algorithm enabled better separation of muscle and nerve fibers.The presented algorithm yields a high quality reconstruction of the LSP bundles that may be helpful both in research and clinical practice. Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
<a href="/cs/project/NV17-28587A" target="_blank" >NV17-28587A: MR traktografie a neurografie u pacientů s poruchami periferního nervového systému</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medicine
ISSN
0025-7974
e-ISSN
—
Svazek periodika
100
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
"art. no. e24646"
Kód UT WoS článku
000640700100083
EID výsledku v databázi Scopus
2-s2.0-85101458220