Implantation of durable left ventricular assist device in patient with postmyocardial infarction ventricular septal defect
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F21%3A00081476" target="_blank" >RIV/00023001:_____/21:00081476 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/21:43921802 RIV/00216208:11110/21:10429568 RIV/00216208:11130/21:10429568
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1111/jocs.15839" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1111/jocs.15839</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jocs.15839" target="_blank" >10.1111/jocs.15839</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Implantation of durable left ventricular assist device in patient with postmyocardial infarction ventricular septal defect
Popis výsledku v původním jazyce
Ventricular septal defect (VSD) is a severe complication of myocardial infarction (MI) with a high mortality rate. We report a case of a large post-MI VSD treated with percutaneous venoarterial extracorporeal membrane oxygenation (VA-ECMO) to restore hemodynamic stability and to avoid surgery in the acute setting. VSD closure with endoventricular patch and implantation of biventricular assist device (BiVAD) was arranged sixteen days after MI. Because of no signs of myocardial recovery, implantation of durable left ventricular assist device (LVAD) as a bridge to transplant was provided, leaving right ventricular assist device (RVAD) to right ventricle recovery. RVAD was explanted 18 days after durable LVAD placement and the patient was discharged home two months after MI. The use of durable LVAD is a unique solution that can be applied in selected patients with MI-VSD and heart failure.
Název v anglickém jazyce
Implantation of durable left ventricular assist device in patient with postmyocardial infarction ventricular septal defect
Popis výsledku anglicky
Ventricular septal defect (VSD) is a severe complication of myocardial infarction (MI) with a high mortality rate. We report a case of a large post-MI VSD treated with percutaneous venoarterial extracorporeal membrane oxygenation (VA-ECMO) to restore hemodynamic stability and to avoid surgery in the acute setting. VSD closure with endoventricular patch and implantation of biventricular assist device (BiVAD) was arranged sixteen days after MI. Because of no signs of myocardial recovery, implantation of durable left ventricular assist device (LVAD) as a bridge to transplant was provided, leaving right ventricular assist device (RVAD) to right ventricle recovery. RVAD was explanted 18 days after durable LVAD placement and the patient was discharged home two months after MI. The use of durable LVAD is a unique solution that can be applied in selected patients with MI-VSD and heart failure.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of cardiac surgery
ISSN
0886-0440
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
3944-3947
Kód UT WoS článku
000675684100001
EID výsledku v databázi Scopus
2-s2.0-85110959969