Acute efficacy of contiguous versus temporally discontiguous point-by-point radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation : a randomized study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F22%3A00083454" target="_blank" >RIV/00023001:_____/22:00083454 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/22:43922755 RIV/00216208:11110/22:10436255 RIV/00216208:11120/22:43922755
Výsledek na webu
<a href="https://link.springer.com/content/pdf/10.1007/s10840-021-01113-9.pdf?pdf=button" target="_blank" >https://link.springer.com/content/pdf/10.1007/s10840-021-01113-9.pdf?pdf=button</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10840-021-01113-9" target="_blank" >10.1007/s10840-021-01113-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Acute efficacy of contiguous versus temporally discontiguous point-by-point radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation : a randomized study
Popis výsledku v původním jazyce
Purpose Durable pulmonary vein (PV) isolation (PVI) determines the clinical success of catheter ablation for atrial fibrillation. In this randomized study, we investigated whether the temporally discontiguous deployment of ablation lesions adversely affected the acute efficacy of PVI. Methods Thirty-six consecutive patients with drug-refractory paroxysmal atrial fibrillation (aged 59 +/- 11, 58% males) were randomized 1:1 to either discontiguous (D-PVI) or contiguous (C-PVI) encircling radiofrequency (RF) lesions around ipsilateral PVs. A contact force-sensing catheter was used targeting a final interlesion distance < 6 mm and the ablation index of 400-450 (anterior wall) and 300-350 (posterior wall). The study endpoint was defined as failure of first-pass PVI or acute PV reconnection during a waiting time (> 30 min) followed by adenosine challenge. Results The total RF time, number of RF lesions, and mean interlesion distance were comparable in both groups. Total endpoint rates were 1/36 (3%) in the D-PVI vs 4/36 (11%) in the C-PVI groups; P = 0.34 for superiority, P = 0.008 for non-inferiority. Adenosine-induced reconnection of right PVs was the only endpoint in the D-PVI group. In the C-PVI group, first-pass PVI failed in 2 right PVs and spontaneous reconnection occurred in 2 other circles (left and right PVs). Conclusion Temporally discontiguous deployment of RF lesions is not associated with lower procedural PVI efficacy when strict criteria for interlesion distance and ablation index are applied. The development of local edema around each ablation site does not prevent effective RF lesion formation at adjacent positions.
Název v anglickém jazyce
Acute efficacy of contiguous versus temporally discontiguous point-by-point radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation : a randomized study
Popis výsledku anglicky
Purpose Durable pulmonary vein (PV) isolation (PVI) determines the clinical success of catheter ablation for atrial fibrillation. In this randomized study, we investigated whether the temporally discontiguous deployment of ablation lesions adversely affected the acute efficacy of PVI. Methods Thirty-six consecutive patients with drug-refractory paroxysmal atrial fibrillation (aged 59 +/- 11, 58% males) were randomized 1:1 to either discontiguous (D-PVI) or contiguous (C-PVI) encircling radiofrequency (RF) lesions around ipsilateral PVs. A contact force-sensing catheter was used targeting a final interlesion distance < 6 mm and the ablation index of 400-450 (anterior wall) and 300-350 (posterior wall). The study endpoint was defined as failure of first-pass PVI or acute PV reconnection during a waiting time (> 30 min) followed by adenosine challenge. Results The total RF time, number of RF lesions, and mean interlesion distance were comparable in both groups. Total endpoint rates were 1/36 (3%) in the D-PVI vs 4/36 (11%) in the C-PVI groups; P = 0.34 for superiority, P = 0.008 for non-inferiority. Adenosine-induced reconnection of right PVs was the only endpoint in the D-PVI group. In the C-PVI group, first-pass PVI failed in 2 right PVs and spontaneous reconnection occurred in 2 other circles (left and right PVs). Conclusion Temporally discontiguous deployment of RF lesions is not associated with lower procedural PVI efficacy when strict criteria for interlesion distance and ablation index are applied. The development of local edema around each ablation site does not prevent effective RF lesion formation at adjacent positions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of interventional cardiac electrophysiology: an international journal of arrhythmias and pacing
ISSN
1383-875X
e-ISSN
1572-8595
Svazek periodika
64
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
661-667
Kód UT WoS článku
000739277700001
EID výsledku v databázi Scopus
2-s2.0-85122309047