The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): fourth Paediatric EUROMACS (Paedi-EUROMACS) report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F24%3A00085011" target="_blank" >RIV/00023001:_____/24:00085011 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/24:00137003
Výsledek na webu
<a href="https://academic.oup.com/ejcts/article-abstract/66/2/ezae276/7717352?redirectedFrom=fulltext" target="_blank" >https://academic.oup.com/ejcts/article-abstract/66/2/ezae276/7717352?redirectedFrom=fulltext</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/ejcts/ezae276" target="_blank" >10.1093/ejcts/ezae276</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): fourth Paediatric EUROMACS (Paedi-EUROMACS) report
Popis výsledku v původním jazyce
OBJECTIVES: The use of ventricular assist devices (VADs) in children is increasing. However, absolute numbers in individual centres and countries remain small. Collaborative efforts such as the Paedi-European Registry for Patients with Mechanical Circulatory Support (EUROMACS) are therefore essential for combining international experience with paediatric VADs. Our goal was to present the results from the fourth Paedi-EUROMACS report. METHODS: All paediatric (<19 years) patients from the EUROMACS database supported by a VAD were included. Patients were stratified into a congenital heart disease (CHD) group and a group with a non-congenital aetiology. End points included mortality, a transplant and recovery. Cox proportional hazard models were used to explore associated factors for mortality, cerebrovascular accident and pump thrombosis. RESULTS: A total of 590 primary implants were included. The congenital group was significantly younger (2.5 vs 8.0 years, respectively, P < 0.001) and was more commonly supported by a pulsatile flow device (73.5% vs 59.9%, P < 0.001). Mortality was significantly higher in the congenital group (30.8% vs 20.4%, P = 0.009) than in the non-congenital group. However, in multivariable analyses, CHD was not significantly associated with mortality [hazard ratio (HR) 1.285; confidence interval (CI) 0.8111-2.036, P = 0.740]. Pump thrombosis was the most frequently reported adverse event (377 events in 132 patients; 0.925 events per patient-year) and was significantly associated with body surface area (HR 0.524, CI 0.333-0.823, P = 0.005), CHD (HR 1.641, CI 1.054-2.555, P = 0.028) and pulsatile flow support (HR 2.345, CI 1.406-3.910, P = 0.001) in multivariable analyses. CONCLUSIONS: This fourth Paedi-EUROMACS report highlights the increasing use of paediatric VADs. The patient populations with congenital and non-congenital aetiologies exhibit distinct characteristics and clinical outcomes.
Název v anglickém jazyce
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): fourth Paediatric EUROMACS (Paedi-EUROMACS) report
Popis výsledku anglicky
OBJECTIVES: The use of ventricular assist devices (VADs) in children is increasing. However, absolute numbers in individual centres and countries remain small. Collaborative efforts such as the Paedi-European Registry for Patients with Mechanical Circulatory Support (EUROMACS) are therefore essential for combining international experience with paediatric VADs. Our goal was to present the results from the fourth Paedi-EUROMACS report. METHODS: All paediatric (<19 years) patients from the EUROMACS database supported by a VAD were included. Patients were stratified into a congenital heart disease (CHD) group and a group with a non-congenital aetiology. End points included mortality, a transplant and recovery. Cox proportional hazard models were used to explore associated factors for mortality, cerebrovascular accident and pump thrombosis. RESULTS: A total of 590 primary implants were included. The congenital group was significantly younger (2.5 vs 8.0 years, respectively, P < 0.001) and was more commonly supported by a pulsatile flow device (73.5% vs 59.9%, P < 0.001). Mortality was significantly higher in the congenital group (30.8% vs 20.4%, P = 0.009) than in the non-congenital group. However, in multivariable analyses, CHD was not significantly associated with mortality [hazard ratio (HR) 1.285; confidence interval (CI) 0.8111-2.036, P = 0.740]. Pump thrombosis was the most frequently reported adverse event (377 events in 132 patients; 0.925 events per patient-year) and was significantly associated with body surface area (HR 0.524, CI 0.333-0.823, P = 0.005), CHD (HR 1.641, CI 1.054-2.555, P = 0.028) and pulsatile flow support (HR 2.345, CI 1.406-3.910, P = 0.001) in multivariable analyses. CONCLUSIONS: This fourth Paedi-EUROMACS report highlights the increasing use of paediatric VADs. The patient populations with congenital and non-congenital aetiologies exhibit distinct characteristics and clinical outcomes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European journal of cardio-thoracic surgery
ISSN
1010-7940
e-ISSN
1873-734X
Svazek periodika
66
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
"art. no. ezae276"
Kód UT WoS článku
001294635400002
EID výsledku v databázi Scopus
2-s2.0-85201988370