The Gastroscopy RAte of Cleanliness Evaluation (GRACE) Scale: an international reliability and validation study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00085453" target="_blank" >RIV/00023001:_____/25:00085453 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.thieme-connect.de/products/ejournals/abstract/10.1055/a-2422-0856" target="_blank" >https://www.thieme-connect.de/products/ejournals/abstract/10.1055/a-2422-0856</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1055/a-2422-0856" target="_blank" >10.1055/a-2422-0856</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Gastroscopy RAte of Cleanliness Evaluation (GRACE) Scale: an international reliability and validation study
Popis výsledku v původním jazyce
Background Muco sal visualization during upper gastrointestinal (UGI) endoscopy can be impaired by the presence of foam, bubbles, and mucus. Some UGI endoscopy visibility scales have been proposed but have not undergone multicenter validation. This study aimed to develop and validate the Gastroscopy RAte of Cleanliness Evaluation (GRACE) scale. Methods A multicenter, international, cross-sectional study was conducted. The GRACE scale is based on a score from 0 (worst) to 3 (excellent) for esophagus, stomach, and duodenum, for a total ranging from 0 to 9. In phase 1, four expert endoscopists evaluated 60 images twice, with a 2week interval between rounds; in phase 2, the same 60 images were scored twice by one expert and one nonexpert endoscopist from 27 endoscopy departments worldwide. For reproducibility assessment and real-time validation, the scale was applied to consecutive patients undergoing gastroscopy at each center. Results On internal validation, interobserver agreement was 0.81 (95 %CI 0.73-0.87) and 0.80 (95 %CI 0.72-0.86), with reliability of 0.73 (95 %CI 0.63-0.82) and 0.72 (95 %CI 0.63-0.81), in the two rounds, respectively. On external validation, overall interobserver agreement was 0.85 (95 %CI 0.82-0.88) and reliability was 0.79 (95 %CI 0.73-0.84). In real-time evaluation, the overall proportion of correct classifications was 0.80 (95 %CI 0.77-0.82). Conclusions The GRACE scale showed good interobserver agreement, reliability, and validity. The widespread use of this scale could enhance quality and standardize the assessment of muco sal cleanliness during UGI endoscopy, pushing endoscopists to strive for excellent visibility and reducing the risk of missed lesions.
Název v anglickém jazyce
The Gastroscopy RAte of Cleanliness Evaluation (GRACE) Scale: an international reliability and validation study
Popis výsledku anglicky
Background Muco sal visualization during upper gastrointestinal (UGI) endoscopy can be impaired by the presence of foam, bubbles, and mucus. Some UGI endoscopy visibility scales have been proposed but have not undergone multicenter validation. This study aimed to develop and validate the Gastroscopy RAte of Cleanliness Evaluation (GRACE) scale. Methods A multicenter, international, cross-sectional study was conducted. The GRACE scale is based on a score from 0 (worst) to 3 (excellent) for esophagus, stomach, and duodenum, for a total ranging from 0 to 9. In phase 1, four expert endoscopists evaluated 60 images twice, with a 2week interval between rounds; in phase 2, the same 60 images were scored twice by one expert and one nonexpert endoscopist from 27 endoscopy departments worldwide. For reproducibility assessment and real-time validation, the scale was applied to consecutive patients undergoing gastroscopy at each center. Results On internal validation, interobserver agreement was 0.81 (95 %CI 0.73-0.87) and 0.80 (95 %CI 0.72-0.86), with reliability of 0.73 (95 %CI 0.63-0.82) and 0.72 (95 %CI 0.63-0.81), in the two rounds, respectively. On external validation, overall interobserver agreement was 0.85 (95 %CI 0.82-0.88) and reliability was 0.79 (95 %CI 0.73-0.84). In real-time evaluation, the overall proportion of correct classifications was 0.80 (95 %CI 0.77-0.82). Conclusions The GRACE scale showed good interobserver agreement, reliability, and validity. The widespread use of this scale could enhance quality and standardize the assessment of muco sal cleanliness during UGI endoscopy, pushing endoscopists to strive for excellent visibility and reducing the risk of missed lesions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30219 - Gastroenterology and hepatology
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Endoscopy
ISSN
0013-726X
e-ISSN
1438-8812
Svazek periodika
57
Číslo periodika v rámci svazku
04
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
312-320
Kód UT WoS článku
001351078200001
EID výsledku v databázi Scopus
2-s2.0-85209235226