Concomitant Surgical Procedures and Aspirin Avoidance With Left Ventricular Assist Device Therapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00085763" target="_blank" >RIV/00023001:_____/25:00085763 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S2213177925001702?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2213177925001702?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jchf.2025.01.017" target="_blank" >10.1016/j.jchf.2025.01.017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Concomitant Surgical Procedures and Aspirin Avoidance With Left Ventricular Assist Device Therapy
Popis výsledku v původním jazyce
Background: ARIES-HM3 (Antiplatelet Removal and Hemocompatibility Events With the HeartMate 3 Pump) demonstrated that aspirin avoidance with a fully magnetically levitated HeartMate 3 (HM3) left ventricular assist device (LVAD) reduces bleeding complications and does not increase thromboembolism. Whether a concomitant surgical procedure modifies the observed safety and benefits remains uncertain. Objectives: This prespecified analysis of ARIES-HM3 studied clinical outcomes when concomitant surgical procedures are performed during LVAD implantation with excluding aspirin but maintaining a vitamin K antagonist. Methods: Among 628 patients randomized to receive either placebo or aspirin with a vitamin K antagonist, 589 (296 placebo and 293 aspirin) contributed to the primary endpoint analysis. Sub-categorization with receiving a concomitant surgical procedure (valvular procedure/coronary artery bypass grafting or nonvalvular procedure) was done and the composite primary endpoint of survival free from major nonsurgical (>14 days postimplant) hemocompatibility-related adverse events at 12 months was assessed. Results: There were 155 (52%) and 145 (49%) concomitant procedures in placebo and aspirin arms, respectively. The percentage of subjects achieving primary endpoint success was higher with the placebo group in patients with a concomitant procedure, and no interaction was observed on primary outcomes between those with and without concomitant surgical procedures (P-int = 0.231, 0.298, and 0.735 for any procedure, valvular/coronary artery bypass grafting, and nonvalvular procedures, respectively). There was a similar reduction in nonsurgical major hemorrhagic events with placebo compared with aspirin, observed in patients with or without any concomitant procedure: 0.64 (95% CI: 0.44-0.94) and 0.66 (95% CI: 0.46-0.93). Conclusions: Our findings support the safety and efficacy of aspirin avoidance from the antithrombotic regimen in HM3 LVAD patients undergoing concomitant surgical procedures. (Antiplatelet Removal and Hemocompatibility Events With the HeartMate 3 Pump [ARIES-HM3]; NCT04069156). (c) 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Název v anglickém jazyce
Concomitant Surgical Procedures and Aspirin Avoidance With Left Ventricular Assist Device Therapy
Popis výsledku anglicky
Background: ARIES-HM3 (Antiplatelet Removal and Hemocompatibility Events With the HeartMate 3 Pump) demonstrated that aspirin avoidance with a fully magnetically levitated HeartMate 3 (HM3) left ventricular assist device (LVAD) reduces bleeding complications and does not increase thromboembolism. Whether a concomitant surgical procedure modifies the observed safety and benefits remains uncertain. Objectives: This prespecified analysis of ARIES-HM3 studied clinical outcomes when concomitant surgical procedures are performed during LVAD implantation with excluding aspirin but maintaining a vitamin K antagonist. Methods: Among 628 patients randomized to receive either placebo or aspirin with a vitamin K antagonist, 589 (296 placebo and 293 aspirin) contributed to the primary endpoint analysis. Sub-categorization with receiving a concomitant surgical procedure (valvular procedure/coronary artery bypass grafting or nonvalvular procedure) was done and the composite primary endpoint of survival free from major nonsurgical (>14 days postimplant) hemocompatibility-related adverse events at 12 months was assessed. Results: There were 155 (52%) and 145 (49%) concomitant procedures in placebo and aspirin arms, respectively. The percentage of subjects achieving primary endpoint success was higher with the placebo group in patients with a concomitant procedure, and no interaction was observed on primary outcomes between those with and without concomitant surgical procedures (P-int = 0.231, 0.298, and 0.735 for any procedure, valvular/coronary artery bypass grafting, and nonvalvular procedures, respectively). There was a similar reduction in nonsurgical major hemorrhagic events with placebo compared with aspirin, observed in patients with or without any concomitant procedure: 0.64 (95% CI: 0.44-0.94) and 0.66 (95% CI: 0.46-0.93). Conclusions: Our findings support the safety and efficacy of aspirin avoidance from the antithrombotic regimen in HM3 LVAD patients undergoing concomitant surgical procedures. (Antiplatelet Removal and Hemocompatibility Events With the HeartMate 3 Pump [ARIES-HM3]; NCT04069156). (c) 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JACC. Heart failure
ISSN
2213-1779
e-ISSN
2213-1787
Svazek periodika
13
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
13
Strana od-do
"art. no. 102411"
Kód UT WoS článku
001533829800007
EID výsledku v databázi Scopus
2-s2.0-105002234818